{"id":572112,"date":"2024-11-05T19:30:50","date_gmt":"2024-11-05T19:30:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/iec-61753-111-082021\/"},"modified":"2024-11-05T19:30:50","modified_gmt":"2024-11-05T19:30:50","slug":"iec-61753-111-082021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/iec\/iec-61753-111-082021\/","title":{"rendered":"IEC 61753-111-08:2021"},"content":{"rendered":"
IEC 61753-111-08:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard for category G – Ground, as defined in Table A.14 of IEC 61753-1:2018. Free breathing closures are not covered in this document. This first edition cancels and replaces IEC 61753-111-8 published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753-111-8:
\na) terms and definitions updated according to IEC 61753-1:2018 and IEC 61756-1:2019;
\nb) test severities updated according to IEC 61753-1:2018;
\nc) sealing tests are done with 20 kPa overpressure;
\nd) pass-fail criterion of pressure loss during test added to mechanical sealing tests;
\ne) vibration sealing test changed to 10 Hz, 3 mm amplitude and 1 000 000 cycles;
\nf) reduced loads added in cable retention test for small diameter cables and tubes;
\ng) reduced loads for cable axial compression test for small diameter cables;
\nh) the duration of the cycles in torsion and bending test is added;
\ni) free fall test removed (is covered by the optical shock test);
\nj) crush resistance test of 1 000 N for 10 min is added;
\nk) assembly and disassembly test: duration reduced to 5 cycles;
\nl) resistance to solvents and contaminating fluids: added immersion in diesel with duration of 1 h and 24 h drying time and added immersion in petroleum jelly for 5 days;
\nm) resistance to stress cracking solvents added for 5 days;
\nn) duration of the change of temperature reduced to 12 cycles;
\no) water immersion test at 1 m for 7 days added.<\/p>\n","protected":false},"excerpt":{"rendered":"
Fibre optic interconnecting devices and passive components – Performance standard – Part 111-08: Sealed closures for category G – Ground<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n IEC<\/b><\/a><\/td>\n 2021-04-07<\/td>\n 34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":572124,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[650,2636],"product_tag":[],"class_list":{"0":"post-572112","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-180-20","7":"product_cat-iec","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/572112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/572124"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=572112"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=572112"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=572112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}