{"id":513194,"date":"2024-11-05T14:22:43","date_gmt":"2024-11-05T14:22:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/can-csa-e61558-112\/"},"modified":"2024-11-05T14:22:43","modified_gmt":"2024-11-05T14:22:43","slug":"can-csa-e61558-112","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/csa\/can-csa-e61558-112\/","title":{"rendered":"CAN\/CSA-E61558-1:12"},"content":{"rendered":"
Preface<\/strong><\/p>\n This is the second edition of CAN\/CSA-E61558-1, Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61558-1 (edition 2:2005 consolidated with Amendment 1:2009). This Standard supersedes the previous edition, published in 2003 as CAN\/CSA-E61558-1, Safety of power transformers, power supply units and similar – Part 1: General requirements and tests (adopted IEC 61558-1:1997+A1:1998). This Standard also replaces CAN\/CSA-E742-94 (adopted IEC 742:1983).<\/p>\n Scope<\/strong><\/p>\n This International Standard deals with safety aspects of power transformers, power supplies, reactors and similar products such as electrical, thermal and mechanical safety.<\/p>\n This Standard covers the following types of dry-type transformers, power supplies, including switch mode power supplies, and reactors, the windings of which may be encapsulated or non-encapsulated :<\/p>\n NOTE 1 The distinction between transformers, power supplies and switch mode power supplies is as follows: <\/p>\n The relevant parts 2 may be found in the introduction of this standard.<\/p>\n a) Stationary or portable, single-phase or poly-phase, air-cooled (natural or forced), isolating and safety isolating transformers, independent or associated, not forming a part of distribution networks and with the following characteristics: <\/p>\n and complying with the following values, unless otherwise specified in the relevant part 2:<\/p>\n * for isolating transformers: <\/p>\n b) Stationary or portable, single-phase or polyphase, air-cooled (natural or forced) separating transformers, auto-transformers, variable transformers and small reactors, independent or associated, not forming a part of distribution networks and with the following characteristics: <\/p>\n and complying with the following values, unless otherwise specified in the relevant part 2: <\/p>\n NOTE 3 Normally, the transformers of type b) are intended to be associated with the equipment to provide voltages different from the supply voltage for the functional requirements of the equipment. The protection against electric shock may be provided or completed by other features of the equipment, such as the body. Parts of output circuits may be connected to the input circuit or to the protective earth.<\/p>\n c) Stationary or portable, single-phase or polyphase, air-cooled (natural or forced), independent or associated power supplies and switch mode power supplies incorporating one or more transformer(s) of type a) or b), not forming a part of distribution networks and with the following characteristics: <\/p>\n and with the following values, unless otherwise specified in the relevant part 2:<\/p>\n * for power supplies and switch mode power supplies incorporating isolating transformers: <\/p>\n * for power supplies and switch mode power supplies incorporating safety isolating transformers: <\/p>\n * for power supplies and switch mode power supplies incorporating separating transformers, auto-transformers , and variable transformers: <\/p>\n NOTE 5 Power supplies and switch mode power supplies incorporating separating transformers are used where double or reinforced insulation between circuits is not required by the installation rules or by the appliance specification. d) This Standard is also applicable to tw-marked transformers with a rated output not exceeding 1 000 VA and where the tw-temperature does not exceed 140 \u00b0C (tw 140). However, tw -marking of transformers is optional.<\/p>\n This Standard also applies to transformers, power supplies, switch mode power supplies, and reactors incorporating electronic circuits.<\/p>\n This Standard does not apply to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformers, power supplies and switch mode power supplies, and reactors.<\/p>\n NOTE 6 Attention is drawn to the following: <\/p>\n NOTE 7 Future technological development of transformers may necessitate a need to increase the upper limit of the frequencies; until then this standard may be used as a guidance document.<\/p>\n","protected":false},"excerpt":{"rendered":" Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Including update no. up to 1:2014)<\/b><\/p>\n\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n CSA<\/b><\/a><\/td>\n 2012<\/td>\n 362<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":513205,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[534,2674],"product_tag":[],"class_list":{"0":"post-513194","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-180","7":"product_cat-csa","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/513194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/513205"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=513194"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=513194"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=513194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}