{"id":400081,"date":"2024-10-20T04:47:20","date_gmt":"2024-10-20T04:47:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-010-2016-2\/"},"modified":"2024-10-26T08:35:13","modified_gmt":"2024-10-26T08:35:13","slug":"ieee-c37-010-2016-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-010-2016-2\/","title":{"rendered":"IEEE C37.010-2016"},"content":{"rendered":"

Revision Standard – Active. The application of indoor and outdoor high-voltage circuit breakers rated above 1000 Vac for use in commercial, industrial, and utility installations is covered in this guide. It deals with usage under varied service conditions, temperature conditions affecting continuous current compensation, reduced dielectrics, reclosing derating as applicable, calculation of system short-circuit current, compensation at different X\/R ratios, detailed calculations with application curves, out-of-phase switching, and general application.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std C37.010\u2122-2016 Front cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nParticipants <\/td>\n<\/tr>\n
9<\/td>\nIntroduction <\/td>\n<\/tr>\n
10<\/td>\nContents <\/td>\n<\/tr>\n
12<\/td>\nList of Figures <\/td>\n<\/tr>\n
14<\/td>\nList of Tables <\/td>\n<\/tr>\n
15<\/td>\nIMPORTANT NOTICE
1.\u2002Overview
1.1\u2002Scope
1.2\u2002Purpose
2.\u2002Normative references <\/td>\n<\/tr>\n
16<\/td>\n3.\u2002General service conditions
3.1\u2002Usual service conditions <\/td>\n<\/tr>\n
17<\/td>\n3.2\u2002Unusual service conditions <\/td>\n<\/tr>\n
21<\/td>\n3.3\u2002Mechanical considerations for outdoor circuit breakers
4.\u2002Application considerations
4.1\u2002General <\/td>\n<\/tr>\n
22<\/td>\n4.2\u2002Maximum voltage for application
4.3\u2002Voltage range factor
4.4\u2002Frequency
4.5\u2002Continuous current <\/td>\n<\/tr>\n
35<\/td>\n4.6\u2002Rated dielectric withstand <\/td>\n<\/tr>\n
36<\/td>\n4.7\u2002Standard operating duty
4.8\u2002Interrupting time <\/td>\n<\/tr>\n
38<\/td>\n4.9\u2002Permissible tripping delay T (determined by short-time current test duration) <\/td>\n<\/tr>\n
39<\/td>\n4.10\u2002Reclosing time <\/td>\n<\/tr>\n
43<\/td>\n4.11\u2002Short-circuit current rating <\/td>\n<\/tr>\n
55<\/td>\n4.12\u2002Transient recovery voltage (TRV)
4.13\u2002Load current switching capability and life (repetitive operation)
4.14\u2002Capacitance current switching <\/td>\n<\/tr>\n
56<\/td>\n4.15\u2002Line closing (line-closing switching surge factor for circuit breakers 362 kV and above) <\/td>\n<\/tr>\n
62<\/td>\n4.16\u2002Switching lines with series capacitors
4.17\u2002Conditions of use with respect to the out-of-phase switching current rating <\/td>\n<\/tr>\n
63<\/td>\n4.18\u2002Shunt reactor current switching <\/td>\n<\/tr>\n
64<\/td>\n4.19\u2002Transformer current switching
4.20\u2002Controlled switching <\/td>\n<\/tr>\n
66<\/td>\n4.21\u2002Transformer limited fault (TLF) duties
4.22\u2002Mechanical endurance <\/td>\n<\/tr>\n
67<\/td>\n4.23\u2002Rated control voltage
4.24\u2002Fluid operating pressure
4.25\u2002Insulating oil for circuit breaker
4.26\u2002Closed pressure system (gas-filled)
4.27\u2002Circuit breakers limiting factors for associated equipment <\/td>\n<\/tr>\n
68<\/td>\n4.28\u2002Circuit breakers equipped with resistors <\/td>\n<\/tr>\n
71<\/td>\n4.29\u2002Service capability
5.\u2002Short-circuit considerations
5.1\u2002System short-circuit currents <\/td>\n<\/tr>\n
74<\/td>\n5.2\u2002Methods for calculating system short-circuit currents <\/td>\n<\/tr>\n
86<\/td>\n5.3\u2002Electrical quantities used <\/td>\n<\/tr>\n
91<\/td>\n5.4\u2002Selection of applicable circuit breaker ratings <\/td>\n<\/tr>\n
93<\/td>\nAnnex\u00a0A (informative) Basis for E\/X method corrected for ac and dc decrements in the calculation of short-circuit currents
A.1\u2002Introduction
A.2\u2002Application methods
A.3\u2002Effects of ac component decrement <\/td>\n<\/tr>\n
98<\/td>\nA.4\u2002Derivation of E\/X multipliers <\/td>\n<\/tr>\n
104<\/td>\nA.5\u2002Longer contact parting time <\/td>\n<\/tr>\n
108<\/td>\nA.6\u2002Accuracy of proposed E\/X multipliers <\/td>\n<\/tr>\n
113<\/td>\nAnnex\u00a0B (informative) Circuit breakers directly connected to motors
B.1\u2002Circuit breakers for ac motor starting <\/td>\n<\/tr>\n
115<\/td>\nB.2\u2002Three-coil trip or equivalent fault protection
B.3\u2002Circuit breakers normally designed for three-phase systems when applied to single-phase systems below 100 kV having one conductor grounded <\/td>\n<\/tr>\n
116<\/td>\nB.4\u2002Neutral grounding circuit breakers <\/td>\n<\/tr>\n
117<\/td>\nAnnex\u00a0C (informative) Bibliography <\/td>\n<\/tr>\n
122<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Application Guide for AC High-Voltage Circuit Breakers > 1000 Vac Rated on a Symmetrical Current Basis<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2016<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":400086,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-400081","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/400081","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/400086"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=400081"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=400081"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=400081"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}