{"id":379447,"date":"2024-10-20T03:02:28","date_gmt":"2024-10-20T03:02:28","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61076-2-0102021\/"},"modified":"2024-10-26T05:27:22","modified_gmt":"2024-10-26T05:27:22","slug":"bs-en-iec-61076-2-0102021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61076-2-0102021\/","title":{"rendered":"BS EN IEC 61076-2-010:2021"},"content":{"rendered":"

IEC 61076-2-010:2021 specifies circular connectors with a push-pull locking mechanism of a size derived from, and thus being compatible with M12 screw-locking connectors (free connectors with screw-locking according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 or IEC 61076-2-113 are compatible with push\u2011pull fixed interfaces according to this document) and with mating interfaces according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 (except codings E in general and coding F for inner push-pull) or IEC 61076-2-113. A fixed connector with push-pull locking according to this document is intermateable with a correspondingly coded free connector with M12 screw-locking according to any of the above mentioned standards. M12 is the dimension of the thread of the screw-locking mechanism of circular connectors with M12 screw-locking. IEC 61076-2-012 defines another inner push-pull for fixed female connectors which is however not compatible to the inner push-pull defined in this document. Annex C shows the different styles of female free connectors to extend male free connectors. This document covers both: a) power connectors with current ratings up to 16 A and voltage ratings up to 630 V, typically used for power supply and power applications in industrial premises, and b) connectors for data and signal transmission with frequencies up to 500 MHz. These connectors consist of both, fixed and free connectors, either rewirable or non-rewirable, with M12 push-pull locking as explained above. Male connectors have round contacts from \u00d8 0,6 mm up to \u00d8 1,5 mm. In addition, the push-pull mechanisms consist of 2 different push-pull designs: c) An outer push-pull for male and female fixed connector, where the locking groove is placed onto the outer cylindric surface of the housing. The outer push-pull for female fixed connectors is made for 2 different types of male connectors. It has locking means for both types on its outer surface. For design and dimensions see 5.3.2 and 5.3.3. d) An inner push-pull for female fixed connectors and for male free connectors, where the locking means are placed onto the inner cylindric surface of the housing. For design and dimensions see 5.3.4. The different codings provided by IEC 61076-2 series detail specifications mentioned within this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces, covered by other standards and the cross-mating between the different codings provided by any other IEC 61076-2 series detail specification mentioned within this document.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
5<\/td>\nAnnex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
9<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
13<\/td>\nFOREWORD <\/td>\n<\/tr>\n
15<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
16<\/td>\nTables
Table 1 \u2013 Content of document <\/td>\n<\/tr>\n
17<\/td>\n1 Scope <\/td>\n<\/tr>\n
18<\/td>\n2 Normative references <\/td>\n<\/tr>\n
19<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
20<\/td>\n4 Technical information
4.1 System of levels
4.1.1 Performance levels
4.1.2 Compatibility levels, according to IEC 61076-1
4.2 Classification into climatic categories
4.3 Contact terminations
4.4 Available connector codings <\/td>\n<\/tr>\n
21<\/td>\nTable 2 \u2013 Available connector codings <\/td>\n<\/tr>\n
22<\/td>\n4.5 Ratings
4.6 Marking
4.7 Safety aspects
5 Dimensional information
5.1 General
5.2 Survey of styles and variants
5.2.1 General
5.2.2 Fixed connectors <\/td>\n<\/tr>\n
23<\/td>\nTable 3 \u2013 Styles of fixed connectors <\/td>\n<\/tr>\n
24<\/td>\nFigures
Figure 1 \u2013 Tube insert, male contacts, thread for M12 screw locking on tube
Figure 2 \u2013 Fixed connector, male contacts, with M12 screw lockingand outer push-pull locking, square flange front mounting <\/td>\n<\/tr>\n
25<\/td>\nFigure 3 \u2013 Fixed connector, male contacts, with M12 screw locking and outer push-pull locking, with wire ends, single hole front mounting thread M16 \u00d7 1,5
Figure 4 \u2013 Fixed connector, male contacts, with M12 screw locking and outerpush-pull locking, with wire ends, single hole front mounting thread M20 \u00d7 1,5 <\/td>\n<\/tr>\n
26<\/td>\nFigure 5 \u2013 Fixed connector, female contacts, with M12 screw locking and outerpush-pull locking, with wire ends, single hole front mounting thread M16 \u00d7 1,5
Figure 6 \u2013 Fixed connector, female contacts, with M12 screw locking and outer push-pull locking, with wire ends, single hole front mounting thread M20 \u00d7 1,5 <\/td>\n<\/tr>\n
27<\/td>\nFigure 7 \u2013 Fixed connector, female contacts, with M12 screw locking andouter push-pull locking, with wire ends, single hole front mountingthread M16 \u00d7 1,5 and mounting orientation
Figure 8 \u2013 Fixed connector, female contacts, with M12 screw locking and outerpush-pull locking, with wire ends, single hole rear mounting thread M16 \u00d7 1,5 <\/td>\n<\/tr>\n
28<\/td>\nFigure 9 \u2013 Fixed connector, female contacts, with M12 screw locking and innerpush-pull locking, with wire ends, single hole front mounting thread M16 \u00d7 1,5
Figure 10 \u2013 Fixed connector, female contacts, with M12 screw locking and innerpush-pull locking, with wire ends, single hole front mounting thread M20 \u00d7 1,5 <\/td>\n<\/tr>\n
29<\/td>\n5.2.3 Free connectors
Figure 11 \u2013 Fixed connector, female contacts, with M12 screw lockingand inner push-pull locking, with wire ends, single hole front mountingthread M16 \u00d7 1,5 and mounting orientation
Figure 12 \u2013 Fixed connector, female contacts, with M12 screw locking and innerpush-pull locking, with wire ends, single hole rear mounting thread M16 \u00d7 1,5 <\/td>\n<\/tr>\n
30<\/td>\nFigure 13 \u2013 Rewirable connector, male contacts,straight version, with outer push-pull locking
Table 4 \u2013 Styles of free connectors
Table 5 \u2013 Dimensions of style JM-OP, Figure 13 <\/td>\n<\/tr>\n
31<\/td>\nFigure 14 \u2013 Rewirable connector, male contacts,angled version, with outer push-pull locking
Figure 15 \u2013 Non-rewirable connector, male contacts,straight version, with outer push pull locking
Table 6 \u2013 Dimensions of style KM-OP, Figure 14 <\/td>\n<\/tr>\n
32<\/td>\nFigure 16 \u2013 Non-rewirable connector, male contacts,angled version, with outer push-pull locking
Table 7 \u2013 Dimensions of style LM-OP, Figure 15
Table 8 \u2013 Dimensions of style MM-OP, Figure 16 <\/td>\n<\/tr>\n
33<\/td>\nFigure 17 \u2013 Rewirable connector, female contacts,straight version, with outer push-pull locking
Table 9 \u2013 Dimensions of style JF-OP, Figure 17 <\/td>\n<\/tr>\n
34<\/td>\nFigure 18 \u2013 Rewirable connector, female contacts,angled version, with outer push-pull locking
Table 10 \u2013 Dimensions of style KF-OP, Figure 18 <\/td>\n<\/tr>\n
35<\/td>\nFigure 19 \u2013 Non-rewirable connector, female contacts,straight version, with outer push-pull locking
Figure 20 \u2013 Non-rewirable connector, female contacts,angled version, with outer push-pull locking
Table 11 \u2013 Dimensions of style LF-OP, Figure 19 <\/td>\n<\/tr>\n
36<\/td>\nFigure 21 \u2013 Rewirable connector, male contacts,straight version, with inner push-pull locking
Table 12 \u2013 Dimensions of style MF-OP, Figure 20
Table 13 \u2013 Dimensions of style JM-IP, Figure 21 <\/td>\n<\/tr>\n
37<\/td>\nFigure 22 \u2013 Rewirable connector, male contacts,angled version, with inner push-pull locking
Figure 23 \u2013 Non-rewirable connector, male contacts,straight version, with inner push-pull locking
Table 14 \u2013 Dimensions of style KM-IP, Figure 22 <\/td>\n<\/tr>\n
38<\/td>\n5.3 Interface dimension
5.3.1 General
Figure 24 \u2013 Non-rewirable connector, male contacts,angled version, with inner push-pull locking
Table 15 \u2013 Dimensions of style LM-IP, Figure 23
Table 16 \u2013 Dimensions of style MM-IP, Figure 24 <\/td>\n<\/tr>\n
39<\/td>\n5.3.2 Outer push-pull locking: male fixed connector side view
Figure 25 \u2013 Outer push-pull locking: male fixed connector side view <\/td>\n<\/tr>\n
40<\/td>\n5.3.3 Outer push-pull locking: female fixed connector side view with details and engage-plane definition for male free cable connectors type 1 and 2
Table 17 \u2013 Dimensions of fixed connector with push pull housing and male contacts <\/td>\n<\/tr>\n
41<\/td>\nFigure 26 \u2013 Outer push-pull locking: female fixed connector side view with detailsand engage-plane definition for male free cable connector <\/td>\n<\/tr>\n
42<\/td>\nTable 18 \u2013 Dimensions for Figure 26 <\/td>\n<\/tr>\n
43<\/td>\n5.3.4 Inner push-pull locking: female fixed connector side view and male free connector side view with details for both
Table 19 \u2013 Dimensions of CA for Figure 26
Table 20 \u2013 Dimensions of CD for Figure 26
Table 21 \u2013 Dimensions of CC for Figure 26 <\/td>\n<\/tr>\n
44<\/td>\nFigure 27 \u2013 Inner push-pull-locking: female fixed connector side viewand male free connector side view with details for both <\/td>\n<\/tr>\n
45<\/td>\nTable 22 \u2013 Dimensions for Figure 27 <\/td>\n<\/tr>\n
46<\/td>\n5.4 Gauges \u2013 Sizing gauges and retention force gauges
6 Characteristics
6.1 Classification into climatic category
6.2 Electrical characteristics
6.2.1 Voltage proof
6.2.2 Rated voltage \u2013 Rated impulse voltage \u2013 Pollution degree
Table 23 \u2013 Dimensions of engage-plane for Figure 27
Table 24 \u2013 Climatic category <\/td>\n<\/tr>\n
47<\/td>\n6.2.3 Current-carrying capacity
6.2.4 Contact resistance
6.2.5 Insulation resistance
6.2.6 Transmission performance
6.3 Mechanical characteristics
6.3.1 Mating interface <\/td>\n<\/tr>\n
48<\/td>\n6.3.2 Push-pull locking mechanism
Table 25 \u2013 Insertion and withdrawal forces for the locking mechanism <\/td>\n<\/tr>\n
49<\/td>\n6.4 Other characteristics
6.4.1 Vibration (sinusoidal)
6.4.2 Shock
6.4.3 Degree of protection provided by enclosures (IP code)
7 Test schedule
7.1 General <\/td>\n<\/tr>\n
50<\/td>\n7.2 Test schedule
7.2.1 Test group P \u2013 Preliminary
7.2.2 Test group AP \u2013 Dynamic\/climatic
7.2.3 Test group BP \u2013 Mechanical endurance
Table 26 \u2013 Number of test specimens
Table 27 \u2013 Test group BP <\/td>\n<\/tr>\n
51<\/td>\n7.2.4 Test group CP \u2013 Electrical load
7.2.5 Test group DP \u2013 Chemical resistivity
7.2.6 Test group EP \u2013 Connection method tests
7.2.7 Test group FP \u2013 Electrical transmission requirements <\/td>\n<\/tr>\n
52<\/td>\nAnnex A (informative)Diameter and position of the female connector body
A.1 Diameter of the female connector body
A.2 Position of female connector body for connectors with outer push-pull locking
Figure A.1 \u2013 Diameter of the female connector body
Table A.1 \u2013 Diameter of the female connector body, dimension X <\/td>\n<\/tr>\n
53<\/td>\nA.3 Position of female connector body for connectors with inner push-pull locking
Figure A.2 \u2013 Position of the female insulating bodyfor connectors with outer push-pull locking
Table A.2 \u2013 Dimension DAB <\/td>\n<\/tr>\n
54<\/td>\nFigure A.3 \u2013 Female fixed connector side view and position of insulating body
Table A.3 \u2013 Dimension FP for Figure A.3 <\/td>\n<\/tr>\n
55<\/td>\nAnnex B (informative)Example for L-coded connector and comparisonbetween screw- and inner push-pull-locking
Figure B.1 \u2013 Dimensions for L-coded interface dimensions according to IEC 610762111 <\/td>\n<\/tr>\n
56<\/td>\nTable B.1 \u2013 Comparison of dimension between screw- and push-pull-locking <\/td>\n<\/tr>\n
57<\/td>\nAnnex C (informative)Styles of female free connectors to extend free male cable connectors
Table C.1 \u2013 Female free connector styles to extend push-pull free male connectors <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Connectors for electrical and electronic equipment. Product requirements – Circular connectors. Detail specification for connectors with outer or inner push-pull locking mechanism, based on mating interfaces according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 and IEC 61076-2-113<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2021<\/td>\n58<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":379455,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[587,2641],"product_tag":[],"class_list":{"0":"post-379447","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-31-220-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/379447","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/379455"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=379447"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=379447"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=379447"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}