{"id":247633,"date":"2024-10-19T16:18:08","date_gmt":"2024-10-19T16:18:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60695-11-22014\/"},"modified":"2024-10-25T11:25:34","modified_gmt":"2024-10-25T11:25:34","slug":"bs-en-60695-11-22014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60695-11-22014\/","title":{"rendered":"BS EN 60695-11-2:2014"},"content":{"rendered":"
This part of IEC 60695 gives the requirements for the production and confirmation of a nominal 1 kW, propane\/air pre-mixed test flame.<\/p>\n
This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO\/IEC Guide 51.<\/p>\n
One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications.<\/p>\n
The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4 Burner\/supply arrangement 4.1 Requirements 4.2 Apparatus and fuel 4.2.1 Burner 4.2.2 Flow control <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4.2.3 Copper block 4.2.4 Thermocouple 4.2.5 Temperature\/time indicating\/recording devices 4.2.6 Laboratory fumehood\/chamber 5 Production of the test flame <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 6 Confirmation of the test flame 6.1 Principle 6.2 Frequency of confirmatory tests 6.3 Procedure <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 7 Recommended arrangements for use of the test flame <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figures Figure 1 \u2013 Flame dimensions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Annex A (normative) Burner construction Figure A.1 \u2013 General assembly <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Figure A.2 \u2013 Pre-mixed burner details <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Figure A.3 \u2013 Pre-mixed burner details <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Figure A.4 \u2013 Pre-mixed burner details <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Figure A.5 \u2013 Pre-mixed burner details <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure A.6 \u2013 Example of supply arrangement for burner Figure A.7 \u2013 Copper block <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure A.8 \u2013 Confirmatory test arrangement <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex B (informative) Examples of test arrangements Figure B.1 \u2013 Examples of test arrangements <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fire hazard testing – Test flames. 1 kW nominal pre-mixed flame: Apparatus, confirmatory test arrangement and guidance<\/b><\/p>\n |