{"id":247252,"date":"2024-10-19T16:16:17","date_gmt":"2024-10-19T16:16:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60794-5-202014\/"},"modified":"2024-10-25T11:22:28","modified_gmt":"2024-10-25T11:22:28","slug":"bs-en-60794-5-202014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60794-5-202014\/","title":{"rendered":"BS EN 60794-5-20:2014"},"content":{"rendered":"
IEC 60794-5-20:2014 is a family specification that covers outdoor microduct fibre units and corresponding microducts and protected microducts for installation by blowing. The protected microducts are intended for duct, directly buried or lashed applications. Microduct fibre units differ from microduct optical fibre cables (see IEC 60794-5-10) in that they provide less protection to the fibres that they contain. Specifically, microduct fibre units rely on the structure of the microduct, protected microduct or appropriate housing to support installation and to provide additional mechanical protection for the optical fibre over the lifetime of the product. Systems built with components covered by this standard are subject to the requirements of sectional specification IEC 60794-5 where applicable.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Symbols <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 General requirements 4.1 Construction 4.1.1 General <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.1.2 Microduct fibre units 4.1.3 Microducts 4.1.4 Protected microducts 4.1.5 Microduct fittings <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.1.6 Microduct hardware 4.2 Optical fibres 4.3 Installation performance tests 4.3.1 Installation conditions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.3.2 Tests applicable 4.3.3 Mechanical and environmental tests 5 Microduct fibre unit 5.1 Tests applicable Tables Table 1 \u2013 Tests applicable for installation performance Table 2 \u2013 Tests applicable for mechanical and environmental performance of microduct fibre unit <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2 Family requirements and test conditions for microduct fibre unit tests 5.3 Tensile performance 5.4 Crush <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.5 Repeated bending 5.6 Torsion 5.7 Kink 5.8 Bend 5.9 Temperature cycling <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.10 Ageing 5.11 Water immersion 5.12 Buffer removal 6 Microduct 6.1 Tests applicable <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.2 Tensile performance 6.3 Crush Table 3 \u2013 Tests applicable for mechanical and environmental performance of microduct <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.4 Impact 6.5 Repeated bending 6.6 Torsion 6.7 Kink 6.8 Bend <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.9 Microduct route verification test 6.10 Microduct pressure withstand 6.11 Ageing 7 Protected microducts 7.1 Tests applicable <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7.2 Tensile performance 7.3 Crush Table 4 \u2013 Tests applicable for mechanical and environmental performance of protected microduct <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7.4 Impact 7.5 Repeated bending 7.6 Kink 7.7 Bend 7.8 Microduct route verification test <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.9 Microduct pressure withstand 7.10 Ageing <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex A (informative) Examples of microduct fibre units, microducts, and protected microducts Figures Figure A.1 \u2013 Protected microducts, tight package Figure A.2 \u2013 Microduct fibre units <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex B (informative) Product descriptions (blank detail specification and minimum requirements) Table B.1 \u2013 Microduct fibre unit description <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Table B.2 \u2013 Microduct description <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Table B.3 \u2013 Protected microduct description <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex C (normative) Product constructions Table C.1 \u2013 Typical microduct fibre unit construction <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Table C.2 \u2013 Microduct construction <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Table C.3 \u2013 Protected microduct construction <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex D (normative) Transmission requirements D.1 Attenuation of cabled fibre Table D.1 \u2013 Multimode maximum cable attenuation coefficient (dB\/km) Table D.2 \u2013 Single-mode maximum cable attenuation coefficient (dB\/km) \u2013 Premises cabling applications <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | D.2 Fibre bandwidth requirements Table D.3 \u2013 Single-mode maximum cable attenuation coefficient (dB\/km) \u2013 All other applications Table D.4 \u2013 Minimum multimode fibre bandwidth (MHz(km) <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex E (normative) IEC 60794-1-21 Method Exx \u2013 Microduct inner clearance test E.1 Object E.2 General E.3 Sample E.4 Test equipment E.5 Procedure E.6 Requirements <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | E.7 Details to be recorded <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Optical fibre cables – Family specification. Outdoor microduct fibre units, microducts and protected microducts for installation by blowing<\/b><\/p>\n |