{"id":243795,"date":"2024-10-19T16:00:22","date_gmt":"2024-10-19T16:00:22","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61784-32010\/"},"modified":"2024-10-25T10:57:32","modified_gmt":"2024-10-25T10:57:32","slug":"bs-en-61784-32010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61784-32010\/","title":{"rendered":"BS EN 61784-3:2010"},"content":{"rendered":"
This part of the IEC 61784-3 series explains some common principles than can be used in the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 series1 for functional safety. These principles can be used in various industrial applications such as process control, manufacturing automation and machinery.<\/p>\n
This part2<\/sup> and the IEC 61784-3-x parts specify several functional safety communication profiles based on the communication profiles and protocol layers of the fieldbus technologies in IEC 61784-1, IEC 61784-2 and the IEC 61158 series.<\/p>\n NOTE 1 Other safety-related communication systems meeting the requirements of IEC 61508 series may exist that are not included in this standard.<\/p>\n NOTE 2 It does not cover electrical safety and intrinsic safety aspects. Electrical safety relates to hazards such as electrical shock. Intrinsic safety relates to hazards associated with potentially explosive atmospheres.<\/p>\n<\/blockquote>\n All systems are exposed to unauthorized access at some point of their life cycle. Additional measures need to be considered in any safety-related application to protect fieldbus systems against unauthorized access. The IEC 62443 series will address many of these issues; the relationship with the IEC 62443 series is detailed in a dedicated subclause of this part.<\/p>\n NOTE 3 Additional profile specific requirements for security may also be specified in IEC 61784-43<\/sup> [10].<\/p>\n NOTE 4 Implementation of a functional safety communication profile according to this part in a device is not sufficient to qualify it as a safety device, as defined in IEC 61508 series.<\/p>\n NOTE 5 The resulting SIL claim of a system depends on the implementation of the selected functional safety communication profile within this system.<\/p>\n<\/blockquote>\n Industrial communication networks. Profiles – Functional safety fieldbuses. General rules and profile definitions<\/b><\/p>\n\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 8<\/td>\n CONTENTS
0 Introduction
0.1 General
0.2 Patent declaration <\/td>\n<\/tr>\n\n 12<\/td>\n Figures
Figure 1 \u2013 Relationships of IEC 61784-3 with other standards (machinery) <\/td>\n<\/tr>\n\n 13<\/td>\n Figure 2 \u2013 Relationships of IEC 61784-3 with other standards (process) <\/td>\n<\/tr>\n \n 15<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 17<\/td>\n 3 Terms, definitions, symbols, abbreviated terms and conventions
3.1 Terms and definitions <\/td>\n<\/tr>\n\n 23<\/td>\n 3.2 Symbols and abbreviated terms <\/td>\n<\/tr>\n \n 24<\/td>\n 4 Conformance <\/td>\n<\/tr>\n \n 25<\/td>\n 5 Basics of safety-related fieldbus systems
5.1 Safety function decomposition
5.2 Communication system
Figure\u00a03 \u2013 Safety communication as a part of a safety function <\/td>\n<\/tr>\n\n 26<\/td>\n Figure\u00a04 \u2013 Example model of a functional safety communication system <\/td>\n<\/tr>\n \n 27<\/td>\n 5.3 Communication errors
Figure\u00a05 \u2013 Example of safety function response time components <\/td>\n<\/tr>\n\n 28<\/td>\n 5.4 Deterministic remedial measures <\/td>\n<\/tr>\n \n 30<\/td>\n 5.5 Relationships between errors and safety measures <\/td>\n<\/tr>\n \n 31<\/td>\n 5.6 Data integrity considerations
Tables
Table\u00a01 \u2013 Overview of the effectiveness of the various measures on the possible errors <\/td>\n<\/tr>\n\n 32<\/td>\n Table\u00a02 \u2013 Definition of items used for calculation of the residual error rate <\/td>\n<\/tr>\n \n 33<\/td>\n 5.7 Relationship between functional safety and security
Figure\u00a06 \u2013 Example application
Table\u00a03 \u2013 Relationship of residual error rate to SIL level <\/td>\n<\/tr>\n\n 34<\/td>\n 5.8 Boundary conditions and constraints
5.9 Installation guidelines
5.10 Safety manual
5.11 Safety policy <\/td>\n<\/tr>\n\n 35<\/td>\n 6 Communication Profile Family 1 (Foundation\u2122 Fieldbus) \u2013 Profiles for functional safety
6.1 Functional Safety Communication Profile 1\/1
6.2 Technical overview <\/td>\n<\/tr>\n\n 36<\/td>\n 7 Communication Profile Family 2 (CIP\u2122) \u2013 Profiles for functional safety
7.1 Functional Safety Communication Profile 2\/1
7.2 Technical overview
Figure\u00a07 \u2013 Scope of FSCP\u00a01\/1 <\/td>\n<\/tr>\n\n 37<\/td>\n Figure\u00a08 \u2013 Relationship of Safety Validators <\/td>\n<\/tr>\n \n 38<\/td>\n 8 Communication Profile Family 3 (PROFIBUS\u2122, PROFINET\u2122) \u2013 Profiles for functional safety
8.1 Functional Safety Communication Profile 3\/1
8.2 Technical overview <\/td>\n<\/tr>\n\n 39<\/td>\n Figure\u00a09 \u2013 Basic communication preconditions for FSCP\u00a03\/1
Figure\u00a010 \u2013 Structure of a FSCP\u00a03\/1 safety PDU <\/td>\n<\/tr>\n\n 40<\/td>\n 9 Communication Profile Family 6 (INTERBUS\u00ae) \u2013 Profiles for functional safety
9.1 Functional Safety Communication Profile 6\/7
Figure\u00a011 \u2013 Safe communication modes <\/td>\n<\/tr>\n\n 41<\/td>\n 9.2 Technical overview
Figure\u00a012 \u2013 FSCP\u00a06\/7 communication preconditions
Table\u00a04 \u2013 Overview of profile identifier usable for FSCP\u00a06\/7 <\/td>\n<\/tr>\n\n 42<\/td>\n 10 Communication Profile Family 8 (CC-Link\u2122) \u2013 Profiles for functional safety
10.1 Functional Safety Communication Profile 8\/1
10.2 Technical overview <\/td>\n<\/tr>\n\n 43<\/td>\n 11 Communication Profile Family 12 (EtherCAT\u2122) \u2013 Profiles for functional safety
11.1 Functional Safety Communication Profile 12\/1
11.2 Technical overview
Figure\u00a013 \u2013 Basic FSCP\u00a012\/1 system <\/td>\n<\/tr>\n\n 44<\/td>\n 12 Communication Profile Family 13 (Ethernet POWERLINK\u2122) \u2013 Profiles for functional safety
12.1 Functional Safety Communication Profile 13\/1
12.2 Technical overview <\/td>\n<\/tr>\n\n 45<\/td>\n 13 Communication Profile Family 14 (EPA\u00ae) \u2013 Profiles for functional safety
13.1 Functional Safety Communication Profile 14\/1
Figure\u00a014 \u2013 Producer consumer example
Figure\u00a015 \u2013 Client server example <\/td>\n<\/tr>\n\n 46<\/td>\n 13.2 Technical overview
Figure\u00a016 \u2013 FSCP\u00a014\/1 safety communication architecture <\/td>\n<\/tr>\n\n 47<\/td>\n Annex A (informative) Example functional safety communication models
Figure\u00a0A.1 \u2013 Model A <\/td>\n<\/tr>\n\n 48<\/td>\n Figure\u00a0A.2 \u2013 Model B
Figure\u00a0A.3 \u2013 Model C <\/td>\n<\/tr>\n\n 49<\/td>\n Figure\u00a0A.4 \u2013 Model D <\/td>\n<\/tr>\n \n 50<\/td>\n Annex B (informative) A safety communication channel model using CRC-based error checking
Figure\u00a0B.1 \u2013 Communication channel with perturbation <\/td>\n<\/tr>\n\n 51<\/td>\n Figure\u00a0B.2 \u2013 Binary symmetric channel (BSC) <\/td>\n<\/tr>\n \n 52<\/td>\n Figure\u00a0B.3 \u2013 Example of a block with message and CRC bits (redundancy code)
Figure\u00a0B.4 \u2013 Block codes for error detection <\/td>\n<\/tr>\n\n 53<\/td>\n Figure\u00a0B.5 \u2013 Proper and improper CRC polynomials
Table\u00a0B.1 \u2013 Example dependency dmin and block length n <\/td>\n<\/tr>\n\n 55<\/td>\n Annex C (informative) Structure of technology-specific parts
Table\u00a0C.1 \u2013 Common subclause structure for technology-specific parts <\/td>\n<\/tr>\n\n 57<\/td>\n Annex D (informative) Assessment guideline <\/td>\n<\/tr>\n \n 59<\/td>\n Figure\u00a0D.1 \u2013 Basic Markov model <\/td>\n<\/tr>\n \n 62<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2010<\/td>\n 66<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":243799,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[385,2641],"product_tag":[],"class_list":{"0":"post-243795","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-25-040-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/243795","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/243799"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=243795"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=243795"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=243795"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}