{"id":215551,"date":"2024-10-19T13:58:30","date_gmt":"2024-10-19T13:58:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-1645-11999\/"},"modified":"2024-10-25T07:00:04","modified_gmt":"2024-10-25T07:00:04","slug":"bs-en-1645-11999","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-1645-11999\/","title":{"rendered":"BS EN 1645-1:1999"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | BRITISH STANDARD <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Foreword to amendment A1 Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references 3 Definitions 4 Testing 5 Design and construction 5.1 Occupancy 5.2 Rigidity <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 5.3 Corner steadies 5.4 Grab handles 5.5 Entrance steps <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 5.6 Doors 6 Internal equipment 6.1 Bunks <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 6.2 Shelves and cupboards 6.3 Cooking appliance 7 Drinking water supply, storage and disposal of waste water (when provided) 7.1 Couplings for drinking water supply <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 7.2 Drinking water 7.3 Waste water disposal tank 7.4 Toilet waste disposal 8 Appliances 8.1 Installation of appliances 8.2 Restriction concerning the supply or use of appliances 9 Classification of thermal insulation and heating <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 10 Installations 10.1 Electricity 10.2 Liquefied petroleum gas (LPG) 10.3 Liquid fuel 11 Ventilation 12 Fire precautions 12.1 Means of escape <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 12.2 Protection of flammable elements 12.3 Hotplates <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 13 Warning notice 13.1 Provision of warning notice 13.2 Content of warning notice <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 14 User\u2019s handbook <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex A (normative) Rigidity test A.1 Principle A.2 Preparation and procedure A.3 Expression of results A.4 Test report <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Annex B (normative) Grab handle test B.1 Principle B.2 Preparation and procedure <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure B.1 – Plan of typical grab handle positions B.3 Expression of results B.4 Test report <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Annex C (normative) Strength of entrance steps C.1 Principle C.2 Preparation and procedure C.3 Expression of results C.4 Test Report <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex D (normative) Slip resistance test D.1 Principle D.2 Preparation and procedure D.3 Expression of results D.4 Test report Annex E (normative) Separate entrance step stability test E.1 Principle E.2 Preparation and procedure <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | E.3 Expression of results Figure E.1 – Stability test of separate entrance step E.4 Test report Annex F (normative) Clear height over bunks F.1 Principle F.2 Preparation and procedure F.3 Expression of results <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | F.4 Test report Annex G (normative) Strength of curtains or nets designed to prevent occupants from falling out of bunks G.1 Principle G.2 Preparation and procedure G.3 Expression of results G.4 Test report Annex H (normative) Mechanical strength of bunks H.1 Principle H.2 Selection of bunk <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | H.3 Preparation and procedure H.4 Expression of results H.5 Test report Annex J (normative) Security of folding bunks J.1 Principle J.2 Preparation and procedure J.3 Expression of results <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | J.4 Test report Annex K (normative) Safety of access to upper bunks K.1 Principle K.2 Preparation and procedure K.2.1 General K.2.2 Attachment and deflection K.3 Expression of results K.4 Test report <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure K.1 – Ladder attachment and deflection <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex L (normative) Measurement of gaps L.1 Cone measuring device Figure L.1 – Cone measuring device L.2 Gaps in the base structure L.3 Measurement of gaps <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex M (normative) Method of calculation M.1 Explanation of terms used M.1.1 Thermal transmittance, M.1.2 Thermal conductivity, \u00c6 M.1.3 Thermal resistance, M.1.4 Surface resistance, Table M.1 – Typical surface resistance values M.2 Objectives of calculation <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | M.3 Method of calculation M.3.1 Table M.2 – Typical thermal conductivity values <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Table M.3 – Typical air space thermal resistances M.3.2 Calculation of thermal transmittance for one caravan wall, Table M.4 – Typical thermal transmittance for windows M.3.3 Calculation of overall thermal transmittance of caravan, <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | M.3.4 Losses of heat via the walls, M.3.5 Losses of heat due to renewal of air, M.3.6 Rated power of heating appliances, M.3.7 Temperature <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Table M.5 – Recording of thermal insulation calculations <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex N (normative) Determination of the thermal transmittance for caravans – Test method <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Figure N.1 – Test temperature diagram Annex P (normative) Zone of risk Annex Q (normative) Test equipment Q.1 Load measuring cell Q.2 Load measuring cell Q.3 Certified weights Q.4 Load spreading platform Q.5 Load spreading platform <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Q.6 Step testing device Figure Q.1 – Typical step testing device Q.7 Flexible load spreading device Figure Q.2 – Typical flexible load spreading device <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Q.8 Step testing plate Q.9 Friction test piece Q.10 Ball Q.11 Cone measuring device Figure Q.3 – Typical friction test piece <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Leisure accommodation vehicles. Caravans – Habitation requirements relating to health and safety<\/b><\/p>\n |