FGI Guidelines Hospital 2018
$121.88
FGI Guidelines for Design and Construction of Hospitals
Published By | Publication Date | Number of Pages |
FGI2018 | 2018 | 384 |
2018 Guidelines for Design and Construction of Hospitals
Changes to the Hospital Guidelines clarify requirements and allow flexibility in some designs to support development of facilities that will be functional over the long term. Key changes affect requirements and recommendations for clinical telemedicine spaces; accommodations for patients of size; mobile/transportable units; sterile processing; and examination, procedure, operating, and imaging rooms.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
6 | Copyright |
9 | Contents |
14 | List of Tables |
15 | Preface |
17 | Acknowledgments |
25 | About the Guidelines |
29 | Major Additions and Revisions |
33 | Glossary |
39 | List of Acronyms |
41 | Part 1 General |
43 | 1.1 Introduction 1.1-1 General 1.1-2 New Construction 1.1-3 Renovation |
45 | 1.1-4 Government Regulations |
46 | 1.1-5 Building Codes and Standards 1.1-6 Equivalency Concepts |
47 | 1.1-7 English/Metric Measurements 1.1-8 Codes, Standards, andOther Documents Referenced in theGuidelines |
53 | 1.2 Planning, Design, Construction, and Commissioning 1.2-1 General |
54 | 1.2-2 Functional Program |
55 | 1.2-3 Space Program |
56 | 1.2-4 Safety Risk Assessment (SRA) |
67 | 1.2-5 Environment of Care Requirements |
70 | 1.2-6 Planning and Design Considerations and Requirements |
81 | 1.2-7 Renovation |
82 | 1.2-8 Commissioning |
85 | 1.2-9 Record Drawings and Manuals |
86 | Table 1.2-1 Safety Risk Assessment (SRA) Components |
87 | Appendix Table A1.2-a Safety Risk Assessment Team Member Expertise |
88 | Table 1.2-2 Infection Control Risk Assessment Design Considerations |
89 | Table 1.2-3 Categorization of Hospital Sites by Exterior Ambient Sound with Design Criteria for Sound Isolation of Exterior Shell in New Construction |
90 | Appendix Table A1.2-b Approximate Distance of Noise Sources for Use in Categorization of Hospitals by Exterior Ambient Sound |
91 | Table 1.2-4 Minimum Design Room-Average Sound Absorption Coefficients |
92 | Table 1.2-5 Maximum Design Criteria for Noise in Interior Spaces Caused by Building Systems |
93 | Table 1.2-6 Design Criteria for Minimum Sound Isolation Performance Between Enclosed Rooms |
94 | Table 1.2-7 Design Criteria for Speech Privacy for Enclosed Rooms and Open-Plan Spaces1 |
95 | Table 1.2-8 Maximum Limits on Floor Vibration Caused by Footfalls in Hospitals |
97 | 1.3 Site 1.3-1 General 1.3-2 Location 1.3-3 Site Features |
99 | 1.3-4 Environmental Pollution Control |
101 | 1.4 Equipment 1.4-1 General |
102 | 1.4-2 Equipment Classification 1.4-3 Equipment Requirements |
103 | 1.4-4 Space Requirements for Equipment |
105 | Part 2 Hospital Facility Types |
107 | 2.1 Common Elements for Hospitals 2.1-1 General 2.1-2 Patient Care Units and Other Patient Care Areas |
120 | 2.1-3 Diagnostic and Treatment Areas |
126 | 2.1-4 Patient Support Facilities |
133 | 2.1-5 General Support Facilities |
142 | 2.1-6 Public and Administrative Areas |
143 | 2.1-7 Design and Construction Requirements |
152 | 2.1-8 Building Systems |
169 | Table 2.1-1 Electrical Receptacles for Patient Care Areas in Hospitals |
171 | Table 2.1-2 Locations for Nurse Call Devices in Hospitals |
173 | Table 2.1-3 Station Outlets for Oxygen, Vacuum (Suction), Medical Air, and Instrument Air Systems in Hospitals |
175 | Table 2.1-4 Hot Water Use—General Hospital |
176 | Appendix Table A2.1-a Maximum Length of Hot Water System Pipe or Tube |
177 | 2.2 Specific Requirements for General Hospitals 2.2-1 General 2.2-2 Patient Care Units |
207 | 2.2-3 Diagnostic and Treatment Facilities |
256 | 2.2-4 Patient Support Facilities |
257 | 2.2-5 General Support Facilities 2.2-6 Public and Administrative Areas 2.2-7 Design and Construction Requirements 2.2-8 Building Systems |
258 | Table 2.2-1 Examination/Treatment, Procedure, and Operating Room Classification |
259 | Table 2.2-2 Classification of Room Types for Imaging Services |
260 | Appendix Table A2.2-a Sound Transmission Loss or Attenuation Through Horizontal and Vertical Barriers in NICUs |
261 | 2.3 Specific Requirements for Freestanding Emergency Care Facilities 2.3-1 General 2.3-2 Reserved 2.3-3 Diagnostic and Treatment Areas |
265 | 2.3-4 Patient Support Facilities 2.3-5 General Support Facilities 2.3-6 Public and AdministrativeAreas |
267 | 2.3-7 Design and Construction Requirements 2.3-8 Building Systems |
269 | 2.4 Specific Requirements for Critical Access Hospitals 2.4-1 General |
270 | 2.4-2 Patient Care Units |
273 | 2.4-3 Diagnostic and Treatment Areas |
276 | 2.4-4 Patient Support Facilities |
277 | 2.4-5 General Support Facilities 2.4-6 Public and Administrative Areas 2.4-7 Design and Construction Requirements |
278 | 2.4-8 Building Systems |
279 | 2.5 Specific Requirements for Psychiatric Hospitals 2.5-1 General |
280 | 2.5-2 Patient Care Units |
286 | 2.5-3 Diagnostic and Treatment Areas |
288 | 2.5-4 Patient Support Facilities 2.5-5 General Support Facilities 2.5-6 Public and Administrative Areas 2.5-7 Design and Construction Requirements |
290 | 2.5-8 Building Systems |
293 | 2.6 Specific Requirements for Rehabilitation Hospitals 2.6-1 General 2.6-2 Patient Care Unit and Living Areas |
296 | 2.6-3 Diagnostic and Treatment Locations |
299 | 2.6-4 Patient Support Facilities 2.6-5 General Support Facilities 2.6-6 Public and Administrative Areas 2.6-7 Design and Construction Requirements 2.6-8 Building Systems |
301 | 2.7 Specific Requirements for Children’s Hospitals 2.7-1 General 2.7-2 Patient Care Units |
307 | 2.7-3 Diagnostic and Treatment Areas |
309 | 2.7-4 Patient Support Facilities 2.7-5 General Support Facilities |
310 | 2.7-6 Public and Administrative Areas 2.7-7 Design and Construction Requirements 2.7-8 Building Systems |
311 | 2.8 Specific Requirements for Mobile/Transportable Medical Units 2.8-1 General |
314 | 2.8-2 Reserved 2.8-3 Diagnostic and Treatment Locations |
316 | 2.8-4 – 2.8-5 Reserved 2.8-6 Public and Administrative Areas 2.8-7 Design and Construction Requirements 2.8-8 Building Systems |
321 | Part 3 Ventilation of Hospitals |
325 | ANSI/ASHRAE/ASHE Standard 170-2017 |
327 | CONTENTS |
328 | 1. PURPOSE 2. SCOPE 3. DEFINITIONS |
330 | 4. COMPLIANCE 5. PLANNING 6. SYSTEMS AND EQUIPMENT |
332 | Table 6.4 Minimum Filter Efficiencies |
333 | Table 6.7.2 Supply Air Outlets |
334 | 7. SPACE VENTILATION—HOSPITAL SPACES |
335 | Table 7.1 Design Parameters—Hospital Spaces (Continued) |
341 | 8. SPACE VENTILATION—OUTPATIENT SPACES |
343 | Table 8.1 Design Parameters—Outpatient Spaces |
349 | 9. SPACE VENTILATION—NURSING HOME SPACES |
351 | Table 9.1 Design Parameters—Nursing Home Spaces |
356 | 10. PLANNING, CONSTRUCTION, AND SYSTEM STARTUP |
357 | 11. NORMATIVE REFERENCES |
358 | INFORMATIVE APPENDIX A—OPERATIONS AND MAINTENANCE (O&M) PROCEDURES A1. O&M in Health Care Facilities A2. Special Maintenance for HVAC Units A3. Air Intake Opening for Areaway Figure A3 Provisions for areaways. |
359 | INFORMATIVE APPENDIX B—INFORMATIVE REFERENCES AND BIBLIOGRAPHY |
360 | INFORMATIVE APPENDIX C—ADDENDA DESCRIPTION INFORMATION Table C-1 ANSI/ASHRAE Addenda to ANSI/ASHRAE Standard 170-2013 |
367 | Index |