NE Lincoln Amendment 2
$6.50
NE – Lincoln – Amendment
Published By | Publication Date | Number of Pages |
NE | N/A | 62 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | List of Sections |
4 | 20.12.010 Adoption of 2009 International Residential Code. 20.12.015 Section R101 Amended; Title, Scope and Purpose. |
5 | 20.12.020 Section R102.1 Amended; Applicability; General. 20.12.025 Section R103 Amended; Department of Building and Safety. 20.12.030 Section R105.2 Amended; Work Exempt From Permit. |
6 | 20.12.035 Section R105.3.1.1 Amended; Determination of Substantially Improved or Substantially Damaged Existing Buildings in Flood Hazard Areas. 20.12.040 Section R105.4.1 Added; Orders Not Stayed. 20.12.045 Section R105.5 Amended; Expiration. |
7 | 20.12.050 Section R106.2 Amended; Site Plan or Plot Plan. 20.12.055 Section R107 and Subsections, Temporary Structures and Uses; Deleted. 20.12.060 Section R108 Amended; Fees. |
10 | 20.12.065 Section R109 Section Heading Amended; Inspections and Surveys. |
11 | 20.12.070 Section R109.1 Amended; Types of Inspections. 20.12.075 Section R109.1.2 Amended; Setback Verification. 20.12.080 Section R109.1.4 Amended; Frame Inspection. 20.12.085 Section R109.1.7 Added; Reinspections. |
12 | 20.12.090 Section R109.5 Added; Address Identification. 20.12.095 Section R110 Amended; Certificate of Occupancy. |
13 | 20.12.100 Section R111 Deleted; Service Utilities. 20.12.105 Section R112 Amended; Board of Appeals. |
14 | 20.12.110 Section R113.3 Amended; Prosecution of Violation. 20.12.115 Section R113.4 Amended; Violation Penalties. 20.12.120 Section R114 Amended; Stop Work Order. |
15 | 20.12.125 Section R115 Added; Demolition of Buildings. 20.12.130 Section R202 Amended; Definitions. 20.12.135 Section R301.2.4 Amended; Floodplain Construction. 20.12.140 Table No. R301.2(1) Amended; Climatic and Geographic Design Criteria. |
16 | 20.12.145 Table R301.5 Amended; Minimum Uniformly Distributed Live Loads. |
17 | 20.12.150 Table R301.7 Amended; Allowable Deflection of Structural Members. 20.12.155 Section R302.1 Amended; Exterior Walls. |
18 | 20.12.160 Table R302.1 Amended; Exterior Walls. 20.12.165 Section R302.2 Amended; Townhouses. 20.12.170 Figure R302.2 (1) Added; Typical Party Wall Section; Two 1 Hour Walls. 20.12.175 Figure R302.2 (2) Added; Typical Party Wall Section; 2 Hour Non Bearing Wall With Parallel Bearing Walls. |
19 | 20.12.180 Figure R302.2 (3) Added; Typical Party Wall Section; One 2 Hour Shaft Wall. 20.12.185 Figure R302.2 (4) Added; Typical Party Wall Section; Single 2 Hour Walls. 20.12.190 Section R302.2.2 Amended; Parapets. 20.12.195 Section R302.2.4 Exception 5 Deleted; Structural Independence. 20.12.200 Section R302.3 Amended; Two-family Dwellings. |
20 | 20.12.205 Section R302.5.2 Deleted; Duct Penetration. 20.12.210 Section R302.6 Amended; Separation Required. 20.12.215 Table R302.6 Amended; Dwelling/Garage Fire Separation. |
21 | 20.12.220 Section R302.12 Amended; Draftstopping. 20.12.225 Section R303.1 Exception 2 Amended; Habitable Rooms. 20.12.230 Section R303.3 Amended; Bathrooms. 20.12.235 Sections R303.4, R303.4.1 and R303.4.2 Deleted; Opening Location. 20.12.240 Section R303.5 Deleted; Outside Opening Protection. 20.12.245 Section R305 Amended; Ceiling Heights. |
22 | 20.12.250 Section R306.2 Amended; Kitchen. 20.12.255 Figure R307.1 Amended; Minimum Fixture Clearances. |
23 | 20.12.260 Section R307.3 Added; Access to Whirlpool Pump. 20.12.265 Section R309.3 Amended; Garages and Carports; Flood Hazard Areas. 20.12.270 Section R309.5 Added; Headroom Clearance. |
24 | 20.12.275 Section R310.1 Amended; Emergency Escape and Rescue Required. 20.12.280 Section R310.1.1 Exception Deleted; Minimum Opening. 20.12.285 Section R310.1.5 Added; Double Hung Egress Window. 20.12.290 Section R310.3 Amended; Bulkhead Enclosures. 20.12.300 R311.3.2 Amended; Floor Elevations for Other Exterior Doors. 20.12.305 Section R311.7 Amended; Stairways. |
27 | 20.12.310 Section R312 Amended; Guards. 20.12.315 Section R313 Deleted; Automatic Fire Sprinkler Systems. 20.12.320 Section R314.3 Amended; Single- and Multiple-Station Smoke Alarms. |
28 | 20.12.325 Section R314.4 Amended; Smoke Alarms; Power Source. 20.12.330 Section R315 Amended; Carbon Monoxide Alarms. 20.12.335 Section 317.1 Amended; Protection of Wood and Wood Based Products Against |
29 | 20.12.340 Section R317.1.2 Deleted; Ground Contact. 20.12.345 Section R317.1.4 Amended; Wood Columns. 20.12.350 R319 Amended; Premises Identification. 20.12.355 Section R320 Deleted; Accessibility. 20.12.360 Section R322 Deleted; Flood-Resistant Construction. |
30 | 20.12.365 Section R401.3 Amended; Foundations; Drainage. 20.12.370 Table R401.4.1 Amended; Load Bearing Values. 20.12.375 Section R403.1 Amended; Footings; General. |
31 | 20.12.380 Section R403.1.1 Amended; Minimum Footing Sizes. 20.12.385 Table R403.1 Amended; Minimum Width of Footings. |
32 | 20.12.390 Figure R403.1(1) Amended; Minimum Footing Reinforcement. 20.12.395 Section R403.1.3.2 Amended; Slabs-on-Ground with Turned-Down Footings. 20.12.400 Section R403.1.4.1 Amended; Frost Protection. 20.12.405 Section R403.1.6 Amended; Foundation Anchorage. |
33 | 20.12.410 Section R403.1.7.3 Amended; Foundation Elevation. 20.12.415 Section R403.3 and Subsections, Tables and Figures Deleted; Frost Protected Shadow Foundations. 20.12.420 Section R403.4 Amended; Footings for Precast Concrete Foundations. 20.12.425 Section R403.4.1 Deleted; Crushed Stone Footings. 20.12.430 Table R403.4 Deleted; Minimum Depth of Crushed Stone Footings. 20.12.435 Table R404.1.1(1) Deleted; Plain Masonry Foundation Walls. 20.12.440 Figure R404.1.1(3) Added; Permanent Masonry Foundation Basement Wall Section. 20.12.445 Table R404.1.2 (1) Deleted; Minimum Horizontal Reinforcement for Concrete Basement Walls. |
34 | 20.12.450 Table R404.1.2(2)Deleted; Minimum Vertical Reinforcement for 6-inch Nominal Flat Concrete Basement Walls. 20.12.455 Table R404.1.2(3) Deleted; Minimum Vertical Reinforcement for 8-inch Nominal Flat Concrete Basement Walls. 20.12.460 Table R404.1.2(4) Deleted; Minimum Vertical Reinforcement for 10-inch Nominal Flat Concrete Basement Walls. 20.12.465 Table R404.1.2(8) Deleted; Minimum Vertical Reinforcement for 6-, 8-, 10- 20.12.470 Table 404.1.2 (9) Deleted; Minimum Spacing for Alternate Bar Size and/or 20.12.475 Section R404.1.2.2 Amended; Reinforcement for Foundation Walls. 20.12.480 Figures R404.1.2.2(1) through R404.1.2.2(9) Added; Reinforcement for Foundation Walls. 20.12.485 Figure R404.1.2.2.1 Added; Deadman/4 foot Concrete Wall. 20.12.490 Section 404.1.5.2 Amended; Concrete Wall Thickness. |
35 | 20.12.495 Figure 404.1.5.2 Added; Garage Stub Wall Foundation Detail. 20.12.500 Section R408.7 Deleted; Flood Resistance. 20.12.505 Section R502.2.3 Amended; Deck Lateral Load Connection. 20.12.510 Section R502.3 Amended; Allowable Joist Spans. 20.12.515 Section R502.7 Amended; Lateral Restraint at Supports. |
36 | 20.12.520 Section R502.10 Amended; Framing of Openings. 20.12.525 Section R601.3 Amended; Vapor Retarders. 20.12.530 Figure R602.10.3.5 Added; Alternate Braced Wall Panel at Garage Door 20.12.535 Figure R602.10.4 Added; Braced Walls Using Continuous OSB Sheathing. 20.12.540 Section R703.1 Amended; Exterior Covering; General. |
37 | 20.12.545 Section R703.2 Amended; Water Resistive Barrier. 20.12.550 Section R703.6.3 Amended; Water-Resistive Barriers. |
38 | 20.12.555 Table R703.7.3.1 Deleted; Allowable Spans for Lintels Supporting Masonry 20.12.560 Section R703.7.3 Deleted; Lintels. 20.12.565 Section R703.7.4 Amended; Anchorage. 20.12.570 Section R703.7.4.2 Deleted; Air Space. 20.12.575 Figure R703.7 Deleted; Masonry Veneer Wall Details. 20.12.580 R703.7.5 Amended; Flashing. 20.12.585 Section R703.7.6 Amended; Weepholes. |
39 | 20.12.590 Section R703.8 Amended; Flashing. 20.12.595 Section R703.9.2.1 Amended; Water-Resistive Barrier. 20.12.600 Section R703.9.2.2 Amended; Installation. 20.12.605 Section R703.12.1 Added; Water-Resistive Barrier; Adhered Masonry Veneer. |
40 | 20.12.610 Section R802.3 Amended; Framing Details. 20.12.620 Section R905.2.7.1 Amended; Ice Barrier. 20.12.625 Section R907.3 Amended; Reroofing; Recovering Versus Replacement. 20.12.630 Section R1003.11 Deleted; Masonry Chimneys; Flue Lining (Material). |
41 | 20.12.635 Section R1003.11.2 Deleted; Flue Linings for Specific Appliances. 20.12.640 Section R1003.11.3 Deleted; Gas Appliances. 20.12.645 Section R1003.11.4 Amended; Pellet Fuel-Burning Appliances. 20.12.650 Section R1003.11.5 Deleted. Oil-fired Appliances. 20.12.655 Section R1003.14 Deleted; Flue Area (Appliance). 20.12.660 Section R1004.4 Deleted; Unvented Gas Log Heaters. 20.12.665 Chapter 11 Amended; Energy Code. |
42 | 20.12.670 Chapters 19 through 22 and 24 through 42 of the International Residential Code Deleted. |
43 | Figure R302.2(1) |
44 | Figure R302.2(2) |
45 | Figure R302.2(3) |
46 | Figure R302.2(4) |
47 | Figure R403.1(1) |
48 | Figure R403.1(1) |
49 | Figure R404.1.1(3) Figure R404.1.1(3) |
50 | Figure R404.1.2.2(1) Figure R404.1.2.2(1) |
51 | Figure R404.1.2.2(2) |
52 | Figure R404.1.2.2(3) |
53 | Figure R404.1.2.2(4) |
54 | Figure R404.1.2.2(5) |
55 | Figure R404.1.2.2(6) |
56 | Figure R404.1.2.2(7) |
57 | Figure R404.1.2.2(8) |
58 | Figure R404.1.2.2(9) |
59 | Figure R404.1.2.2.1 |
60 | Figure R404.1.5.2 |
61 | Figure 602.10.3.5 |
62 | Figure R602.10.4 |