Shopping Cart

No products in the cart.

ICC IECC Commentary 2012

$35.21

International Energy Conservation Code and Commentary

Published By Publication Date Number of Pages
ICC 2012 331
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This comprehensive publication provides a convenient reference for regulations in the 2012 International Energy Conservation Code

PDF Catalog

PDF Pages PDF Title
1 2012 IECC® CODE AND COMMENTARY
2 2012 IECC® CODE AND COMMENTARY TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 IECC—COMMERCIAL PROVISIONS
10 CHAPTER 1[CE]: SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
14 FIGURE C101.4.6 MIXED OCCUPANCY
17 SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
18 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION C103 CONSTRUCTION DOCUMENTS
20 SECTION C104 INSPECTIONS
22 SECTION C105 VALIDITY
SECTION C106 REFERENCED STANDARDS
23 SECTION C107 FEES
SECTION C108 STOP WORK ORDER
24 SECTION C109 BOARD OF APPEALS
BIBLIOGRAPHY
26 CHAPTER 2[CE]: DEFINITIONS
SECTION C201 GENERAL
27 SECTION C202 GENERAL DEFINITIONS
28 FIGURE C202(1) BASEMENT WALLS
30 TABLE C202(1) BUILDING ENVELOPE COMPONENTS
36 FIGURE C202(2) HEAT TRAPS ON A TANK WITH CONNECTIONS ON THE BOTTOM
42 BIBLIOGRAPHY
44 CHAPTER 3[CE]: GENERAL REQUIREMENTS
45 SECTION C301 CLIMATE ZONES
47 FIGURE C301.1 CLIMATE ZONES
48 FIGURE C301.3 CLIMATE ZONE DEFINITIONS
49 TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
50 TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
51 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
52 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
53 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
54 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
55 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
56 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
57 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
58 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
59 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
60 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
61 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
62 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
63 SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
64 FIGURE C303.1.1 SAMPLE CERTIFICATE OF INSULATION
66 TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
FIGURE C303.1.3(1) SAMPLE NATIONAL FENESTRATION RATING COUNCIL (NFRC) LABEL
67 TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
FIGURE C303.1.3(2) VISUALLY VERIFIABLE WINDOW CHARACTERISTICS
68 BIBLIOGRAPHY
70 CHAPTER 4[CE]: COMMERCIAL ENERGY EFFICIENCY
TABLE 4C(1) EXAMPLES OF BUILDING TYPES COVERED BY CHAPTER 4[CE]
71 SECTION C401 GENERAL
72 SECTION C402 BUILDING ENVELOPE REQUIREMENTS
73 FIGURE C402.1(1) GRAPHIC SUMMARY OF ENVELOPE REQUIREMENTS
75 FIGURE C402.1.1 HOW TO MEASURE SURFACE AREAS [SEE COMMENTARY FIGURE C402.1(1)]
76 FIGURE C402.2.1 REQUIREMENT FOR ROOFS
77 TABLE C402.1.2 OPAQUE THERMAL ENVELOPE ASSEMBLY REQUIREMENTSa
78 TABLE C402.2 OPAQUE THERMAL ENVELOPE REQUIREMENTSa
79 TABLE C402.2.1.1 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa
80 FIGURE C402.2.3 REQUIREMENTS FOR EXTERIOR ABOVE-GRADE WALLS
81 FIGURE C402.2.4 R-VALUE REQUIREMENTS FOR BELOW-GRADE WALLS
82 FIGURE C402.2.5 R-VALUE REQUIREMENTS FOR FLOORS
83 FIGURE C402.2.6 REQUIREMENT FOR INSULATING SLABS-ON-GRADE
84 TABLE C402.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION
85 EQUATION C4-1
86 EQUATION C4-2
87 FIGURE C402.3.2 WINDOW PROJECTION FACTOR
TABLE C402.3.3.1 SHGC ADJUSTMENT MULTIPLIERS
89 FIGURE C402.4.1 REQUIREMENTS FOR SEALING THE BUILDING ENVELOPE
91 TABLE C402.4.3 MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES
93 FIGURE C402.4.6 VESTIBULES
94 FIGURE C402.4.7 IC-RATED RECESSED LIGHT
SECTION C403 BUILDING MECHANICAL SYSTEMS
TABLE C403.1 MECHANICAL SYSTEMS
99 EQUATION 4C-3
EQUATION 4C-4
100 TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
101 TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
102 TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
103 TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
104 TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
105 TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
106 TABLE 403.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
107 TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.2.3(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
108 TABLE C403.2.3(7) MINIMUM EFFICIENCY REQUIREMENTS: WATER CHILLING PACKAGESa
109 TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
TABLE C403.2.3(9) HEAT TRANSFER EQUIPMENT
110 FIGURE C403.2.4.1 THERMOSTAT TEMPERATURE CONTROL
111 FIGURE C403.2.4.1(1) SEPARATE COOLING AND HEATING SYSTEMS WITHIN A GROUP OF ZONES
112 FIGURE C403.2.4.1(2) INDEPENDENT PERIMETER ZONE HEATING SYSTEM
113 FIGURE C403.2.4.2 DEAD BAND THERMOSTAT CONTROL
118 TABLE C403.2.6 ENERGY RECOVERY REQUIREMENT
119 FIGURE C403.2.7 DUCT INSULATION
122 EQUATION C4-5
123 TABLE C403.2.8 MINIMUM PIPE INSULATION THICKNESS (thickness in inches)a, c
124 TABLE C403.2.10.1(1) FAN POWER LIMITATION
125 TABLE C403.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
126 FIGURE C403.3 COMPLIANCE EVALUATION FOR HVAC SYSTEMS
127 TABLE C403.3.1(1) ECONOMIZER REQUIREMENTS
TABLE C403.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
128 TABLE C403.3.1.1.3(1) HIGH-LIMIT SHUTOFF CONTROL OPTIONS FOR AIR ECONOMIZERS
129 TABLE C403.3.1.1.3(2) HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS
131 FIGURE C403.4.1(1) AIR ECONOMIZER OPERATION
132 FIGURE C403.4.1(2) “STRAINER-CYCLE” WATER ECONOMIZER
133 FIGURE C403.4.1(3) WATER PRECOOLING ECONOMIZER WITH TWO-WAY VALVES
134 FIGURE C403.4.1(4) AIR PRECOOLING WATER ECONOMIZER
136 FIGURE C403.4.2 PART-LOAD CURVES FOR A VARIETY OF FANS
143 TABLE C403.4.7 MAXIMUM HOT GAS BYPASS CAPACITY
SECTION C404 SERVICE WATER HEATING (MANDATORY)
144 FIGURE C404.1 ELEMENTS COVERED BY SECTION C404
146 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
147 FIGURE C404.4(1) HEAT TRAP AND INSULATION REQUIREMENTS FOR NONCIRCULATING SYSTEMS
FIGURE C404.4(2) HEAT TRAPS ON A TANK WITH CONNECTIONS ON THE BOTTOM
148 FIGURE C404.4(3) HEAT TRAP THROUGH A FLEXIBLE PIPE LOOP
FIGURE C404.4(4) HEAT TRAPS ON A TANK WITH CONNECTIONS ON SIDES
150 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
152 TABLE C405.1(1) INPUT WATTAGE COMPARISON (TYPICAL PERFORMANCE)
153 TABLE C405.1(2) EFFICACY OF STANDARD LAMP TYPES
TABLE C405.1(3) TYPICAL LIGHTING POWER FOR MAGNETICALLY BALLASTED FLUORESCENT LAMP-BALLAST SYSTEMS (watts)
154 TABLE C405.1(4) TYPICAL LIGHTING POWER FOR ELECTRONICALLY BALLASTED RAPID START FLUORESCENT LAMP-BALLAST SYSTEMS (watts)
155 TABLE C405.1(5) TYPICAL LIGHTING POWER FOR ELECTRONICALLY BALLASTED INSTANT START FLUORESCENT LAMP-BALLAST SYSTEMS (watts)
156 TABLE C405.1(6)TYPICAL LIGHTING POWER FOR ELECTRONICALLY BALLASTED LOW WATTAGE-REDUCED OUTPUT FLUORESCENT LAMP BALLAST
157 TABLE C405.1(7) TYPICAL LIGHTING POWER FOR COMPACT FLUORESCENT LAMPS
158 TABLE C405.1(8) TYPICAL LIGHTING POWER FOR HIGH INTENSITY DISCHARGE LAMPS
164 FIGURE C405.2.1 REQUIRED LIGHTING CONTROLS
167 FIGURE C405.2.2.1 LIGHT-REDUCTION CONTROLS
168 FIGURE C405.2.2.3(1) ILLUSTRATIONS OF DAYLIGHT ZONES
170 FIGURE C405.3(1) TANDEM BALLASTING REQUIREMENTS
171 FIGURE C405.5 APPLYING THE LIGHTING REQUIREMENTS TO A PRIVATE OFFICE
174 FIGURE C405.5.2 MULTIUSE FACILITY
175 TABLE C405.5.2(1) TOTAL LIGHTING POWER ALLOWANCE CALCULATION USING THE BUILDING AREA METHOD
TABLE C405.5.2(2) TOTAL LIGHTING POWER ALLOWANCE CALCULATION USING THE SPACE-BY-SPACE METHOD
176 TABLE C405.5.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.5.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
177 TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
178 FIGURE C405.6.1 ENERGY-EFFICIENT LIGHTING SOURCE
180 TABLE C405.6.2(1) EXTERIOR LIGHTING ZONES
SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
181 TABLE C405.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
182 TABLE C406.2(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, EFFICIENCY REQUIREMENTS
TABLE C406.2(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, EFFICIENCY REQUIREMENTS
TABLE C406.2(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINALHEAT PUMPS
183 TABLE C406.2(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, EFFICIENCY REQUIREMENTS
TABLE C406.2(5) BOILER, EFFICIENCY REQUIREMENTS
184 TABLE C406.2(6) CHILLERS—EFFICIENCY REQUIREMENTS
185 TABLE C406.2(7) ABSORPTION CHILLERS—EFFICIENCY REQUIREMENTS
TABLE C406.3 REDUCED INTERIOR LIGHTING POWER
SECTION C407 TOTAL BUILDING PERFORMANCE
189 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
190 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
191 TABLE C407.5.1(2) HVAC SYSTEMS MAP
192 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
193 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
195 SECTION C408 SYSTEM COMMISSIONING
197 BIBLIOGRAPHY
200 CHAPTER 5[CE]: REFERENCED STANDARDS
201 FIGURE 5[CE] REFERENCED STANDARDS
202 AAMA
AHAM
AHRI
203 AMCA
ANSI
ASHRAE
ASTM
204 CSA
CTI
DASMA
205 DOE
ICC
IESNA
ISO
206 NFRC
SMACNA
UL
US-FTC
WDMA
208 INDEX
216 IECC—RESIDENTIAL PROVISIONS
218 CHAPTER 1[RE]: SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS
222 FIGURE 101.4.6 MIXED OCCUPANCY
224 SECTION R102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
225 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION R103 CONSTRUCTION DOCUMENTS
227 SECTION R104 INSPECTIONS
229 SECTION R105 VALIDITY
SECTION R106 REFERENCED STANDARDS
230 SECTION R107 FEES
SECTION R108 STOP WORK ORDER
231 SECTION R109 BOARD OF APPEALS
BIBLIOGRAPHY
234 CHAPTER 2[RE]: DEFINITIONS
SECTION R201 GENERAL
235 SECTION R202 GENERAL DEFINITIONS
236 FIGURE R202(1) BASEMENT WALLS
238 TABLE R202(1) BUILDING ENVELOPE COMPONENTS
248 BIBLIOGRAPHY
250 CHAPTER 3[RE]: GENERAL REQUIREMENTS
251 SECTION R301 CLIMATE ZONES
253 FIGURE R301.1 CLIMATE ZONES
254 FIGURE R301.3 CLIMATE ZONE DEFINITIONS
255 TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
256 TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
257 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
258 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
259 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
260 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
261 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
262 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
263 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
264 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
265 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
266 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
267 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
268 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
269 SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
270 FIGURE R303.1.1 SAMPLE CERTIFICATE OF INSULATION
272 TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
FIGURE R303.1.3(1) SAMPLE NATIONAL FENESTRATION RATING COUNCIL (NFRC) LABEL
273 TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
FIGURE R303.1.3(2) VISUALLY VERIFIABLE WINDOW CHARACTERISTICS
274 BIBLIOGRAPHY
276 CHAPTER 4[RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
277 FIGURE R401.1(1) CONDITIONED ENVELOPE
FIGURE R401.1(2) BUILDING ENVELOPE
278 SECTION R402 BUILDING THERMAL ENVELOPE
FIGURE R401.3 CERTIFICATE
280 TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
281 FIGURE R402.1.2 EXTERIOR R-VALUES
283 TABLE R402.1.3 EQUIVALENT U-FACTORSa
285 FIGURE R402.2.1(1) TYPICAL ROOF ASSEMBLY
FIGURE R402.2.1(2) RAISED-HEEL TRUSS
287 FIGURE R402.2.4(1) EXTERIOR INSULATION
FIGURE R402.2.4(2) INTERIOR INSULATION
288 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
289 FIGURE R402.2.8(1) WALKOUT BASEMENT
FIGURE R402.2.8(2) EXTERIOR BASEMENT INSULATION
290 FIGURE R402.2.9 SLAB INSULATION METHODS
291 FIGURE R402.2.10 CRAWL SPACE WALL INSULATION
295 FIGURE R402.4 TYPICAL SOURCES OF AIR LEAKAGE IN THE HOME
296 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION
298 FIGURE R402.4.3 IC-RATED RECESSED LIGHT
299 SECTION R403 SYSTEMS
301 TABLE R403.4.2 MAXIMUM RUN LENGTH (feet)a
TABLE R403.5.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY
303 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
313 BIBLIOGRAPHY
314 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
315 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
316 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
318 CHAPTER 5[RE]: REFERENCED STANDARDS
319 FIGURE 5[RE] REFERENCED STANDARDS
320 AAMA
ACCA
ASHRAE
ASTM
CSA
321 ICC
NFRC
US-FTC
WDMA
322 INDEX
ICC IECC Commentary 2012
$35.21