Electrical insulation systems (EIS). Thermal evaluation of combined liquid and solid components – General requirements

Published By Publication Date Number of Pages
BSI 2011 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC/TS 62332 is applicable to EIS containing solid and liquid components where the thermal stress is the dominant ageing factor, without restriction to voltage class.

This part specifies a dual-temperature test procedure for the thermal evaluation and qualification of electrical insulation systems (EIS).

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
6 FOREWORD
8 INTRODUCTION
9 1 Scope
2 Normative references
10 3 Terms and definitions
12 4 Thermal ageing test apparatus
4.1 General description
4.2 Construction of the test apparatus
13 Figure 1 – Ageing cell cross-section
14 4.3 Monitoring and data collection
5 Construction of the test object
5.1 General
5.2 Determination of component volumes
5.3 Test object
15 Figure 2 – Example of an insulation package for a transformer winding
16 6 Test procedures
6.1 General
6.2 Preparation of the test objects
17 6.3 Diagnostic tests
18 6.4 Thermal ageing
Table 1 – Recommended ageing temperatures and periods for expected thermal class
19 6.5 End-point testing
7 Analysis of data
7.1 End-point criteria
20 7.2 Report
21 Annex A (informative)
Component volume ratio spreadsheet example
Table A.1 – Examples of component volume ratio calculations
22 Bibliography
BSI DD IEC/TS 62332-1:2011