BSI DD IEC/TS 60034-17:2006

$102.76

Rotating electrical machines – Cage induction motors when fed from converters. Application guide

Published By Publication Date Number of Pages
BSI 2006 22
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This technical specification deals with the steady-state operation of cage induction motors within the scope of IEC 60034-12, when fed from converters. It covers the operation over the whole speed setting range, but does not deal with starting or transient phenomena.

Only indirect type converters are dealt with. This type comprises converters with impressed direct current in the intermediate circuit (current source converters) and converters with impressed d.c. voltage (voltage source converters), either of the block type or the pulse controlled type, without restriction on pulse number, pulse width or switching frequency. For the purposes of this technical specification, a converter may include any type of electronic switching device, for example transistors (bipolar or MOSfet), IGBTs, thyristors, GTOthyristors, etc. with analog or digital control electronics.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
5 INTRODUCTION
6 1 Scope
2 Normative references
3 Characteristics of the motor
7 4 Frequency spectrum of voltage and/or currents
Figure 1 – Waveform of phase current iphase in delta connection for current source converter supply (idealized example)
8 Figure 2 – Waveform of line-to-line voltage uLL for voltage source converter supply with switching frequency fs = 30 x f1 (example)
9 5 Losses caused by harmonics
Figure 3 – Example for the dependence of the motor losses caused by harmonics Ph, related to the losses Pf1 at operating frequency f1, on the switching frequency fs in case of voltage source converter supply
11 Figure 4 – Influence of converter supply on the losses of a cage induction motor (frame size 315 M, design N) with rated values of torque and speed
12 6 Torque derating during converter operation
Figure 5 – Fundamental voltage U1 as a function of operating frequency f1 (see clause 6)
13 7 Oscillating torques
Figure 6 – Torque derating factor for cage induction motors of design N, IC 0141 (self-circulating cooling) for current source converter supply as a function of operating frequency f1 (example)
14 8 Magnetically excited noise
15 9 Service life of the insulation system
16 Figure 7 – Limiting curve of admissible impulse voltage ÛLL (including voltage reflection and damping) at the motor terminals as a function of the rise time tr
Figure 8 – Definition of the peak rise time tr of the voltage at the motor terminals
17 10 Bearing currents
Figure 9 – Ring flux including shaft voltage and resulting circulating current icirc
19 Figure 10 – Common mode circuit model and bearing voltage ubrg
20 11 Installation (cabling, grounding, bonding)
12 Maximum safe operating speed
21 13 Power factor correction