BS EN ISO 8655-2:2002 2009
$142.49
Piston-operated volumetric apparatus – Piston pipettes
Published By | Publication Date | Number of Pages |
BSI | 2009 | 24 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | TitlePage – Piston-operated volumetric apparatus�— |
7 | TableofContent – Contents Page |
8 | Foreword – Foreword |
9 | Introduction – Introduction |
11 | Scope – 1��� Scope NormativeReference – 2��� Normative references |
12 | Clause1 – 4��� Principle of operation Clause1 – 5��� Design Subclause2 – 5.1��� Types of piston pipette Subclause2 – 5.2��� Adjustment UntitledSubclause3 – 5.2.1��� A piston pipette shall be adjusted by its manufacturer for the deli… |
13 | UntitledSubclause3 – 5.2.2��� Some piston pipettes have provision for adjustment by the user when… UntitledSubclause3 – 5.2.3��� Some piston pipettes are designed to have their factory-preset adju… Subclause2 – 5.3��� Transfer of hand warmth |
14 | Subclause2 – 5.4��� Pipette tips Subclause3 – 5.4.1��� General UntitledSubclause4 – 5.4.1.1��� The dispensing orifice of the tip shall be shaped in such a way t… UntitledSubclause4 – 5.4.1.2��� In the case of sterilizable pipette tips the sterilization proced… Subclause3 – 5.4.2��� Air-displacement pipette tips UntitledSubclause4 – 5.4.2.1��� Air-displacement pipette tips shall be disposable parts, usually … UntitledSubclause4 – 5.4.2.2��� Tips for piston pipettes with air interface shall be fitted in ac… UntitledSubclause4 – 5.4.2.3��� The form of the pipette tips to be used with a multi-channel pist… Subclause3 – 5.4.3��� Positive-displacement pipette tips UntitledSubclause4 – 5.4.3.1��� Positive-displacement pipette tips shall consist of a plunger and… UntitledSubclause4 – 5.4.3.2��� The shape and material of the plunger and capillary shall confer … UntitledSubclause4 – 5.4.3.3��� Sterilizability shall be in accordance with Subclause2 – 5.5��� Type evaluation |
15 | Clause1 – 6��� Type, designation Clause1 – 7��� Metrological performance requirements Subclause2 – 7.1��� General Subclause3 – 7.1.1��� Conformity tests Subclause3 – 7.1.2��� User tests |
16 | Subclause2 – 7.2��� Fixed-volume piston pipettes of types�A and D1 Subclause2 – 7.3��� Fixed-volume piston pipettes of type�D2 Subclause2 – 7.4��� Variable-volume piston pipettes |
17 | Subclause2 – 7.5��� Multi-channel piston pipettes Subclause2 – 7.6��� Pipette tips |
18 | Clause1 – 8��� Marking Subclause2 – 8.1��� Piston pipettes Subclause2 – 8.2��� Pipette tips |
19 | AnnexNormative – Information to be provided by the supplier for the user of piston pipettes and tips Clause1 – A.1��� Piston pipettes Clause1 – A.2��� Pipette tips and accessories |
20 | AnnexInformative – Possible sources of error for piston pipettes with air interface |
21 | Bibliography – Bibliography |