BS EN ISO 10360-2:2009:2010 Edition
$167.15
Geometrical product specifications (GPS). Acceptance and reverification tests for coordinate measuring machines (CMM) – CMMs used for measuring linear dimensions
Published By | Publication Date | Number of Pages |
BSI | 2010 | 38 |
This part of ISO 10360 specifies the acceptance tests for verifying the performance of a coordinate measuring machine (CMM) used for measuring linear dimensions as stated by the manufacturer. It also specifies the reverification tests that enable the user to periodically reverify the performance of the CMM.
The acceptance and reverification tests given in this part of ISO 10360 are applicable only to Cartesian CMMs using contacting probing systems of any type operating in the discrete-point probing mode.
This part of ISO 10360 does not explicitly apply to:
-
non-Cartesian CMMs; however, parties may apply this part of ISO 10360 to non-Cartesian CMMs by mutual agreement;
-
CMMs using optical probing; however, parties may apply this approach to optical CMMs by mutual agreement.
This part of ISO 10360 specifies performance requirements that can be assigned by the manufacturer or the user of a CMM, the manner of execution of the acceptance and reverification tests to demonstrate the stated requirements, rules for proving conformance, and applications for which the acceptance and reverification tests can be used.
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | Scope Normative references |
10 | Terms and definitions |
12 | Symbols Environmental and metrological requirements Environmental conditions |
13 | Operating conditions Length measurement error, EL Repeatability range of the length measurement error, R0 Workpiece loading effects |
14 | Acceptance tests and reverification tests General Principle |
15 | Length measurement error with zero ram axis stylus tip offse General Measuring equipment |
16 | Procedure Measurement positions Measurement procedure |
17 | Low CTE case Derivation of test results Repeatability range of the length measurement error, R0 |
18 | Length measurement error with ram axis stylus tip offset of Measuring equipment Procedure Probe orientations Possible measurement positions and probe orientations |
19 | Measurements |
20 | Derivation of test results Dual ram CMMs Simplex operating mode Duplex operating mode |
21 | Compliance with specifications Acceptance test Acceptance criteria |
22 | Data rejection and repeated measurements Length measurement error with zero ram axis stylus tip offse Repeatability range of the length measurement error, R0 Length measurement error with ram axis stylus tip offset of Reverification test Applications Acceptance test |
23 | Reverification test Interim check Indication in product documentation and data sheets |