BS EN 15651-4:2017:2018 Edition
$142.49
Sealants for non-structural use in joints in buildings and pedestrian walkways – Sealants for pedestrian walkways
Published By | Publication Date | Number of Pages |
BSI | 2018 | 28 |
This European Standard specifies definitions and requirements for cold applied non-structural elastic sealants used for movement joints in floors in building construction for interior and exterior use.
Areas of application are: floor joints designed for pedestrian walkways, public areas, movement joints between concrete slabs, areas with pedestrian load, areas used with trolleys, walkable floors, balconies, terraces, warehouses.
NOTE Provisions on assessment and verification of constancy of performance – AVCP (i.e. Product type determination and Factory Production Control) and marking of these products are given in EN 15651‑5.
Chemical containment, cold applied joint sealants for concrete pavements to be used in roads, airfields and sewage treatment plants, perimeter seals and seals in wood floors are excluded.
This European Standard does not apply to non-structural sealants in any of non-paste form, to those used in pedestrian walkways.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references |
8 | 3 Terms and definitions 4 Requirements 4.1 Identification requirements 4.1.1 Short description of the sealant |
9 | 4.1.2 Thermogravimetric test 4.1.3 Density 4.1.3.1 Principal 4.1.3.2 Method 4.1.4 Indentation hardness (Shore hardness) 4.2 Conditioning, test procedure and substrates 4.2.1 General 4.2.2 Classification 4.2.2.1 General |
10 | 4.2.2.2 Classification according to the movement capability 4.2.2.3 Classification according to the secant tensile modulus |
11 | 4.2.3 Test procedure |
12 | 4.3 Performance requirements and test methods for non-structural sealants for pedestrian walkways 4.3.1 General 4.3.2 Sealants in pedestrian walkways used in cold climates 4.3.2.1 General |
13 | 4.3.2.2 Tensile properties – Secant modulus to EN ISO 8339:— test procedure at (- 30 ± 2) °C 4.3.2.3 Tensile properties at maintained extension to EN ISO 8340:— test procedure at (- 30 ± 2) °C 4.3.3 Resistance to flow for non-sagging sealants 4.3.4 Sealants with self-levelling properties 4.3.5 Tear resistance |
15 | 4.4 Additional performance requirements for exterior applications 4.4.1 General 4.4.2 Artificial weathering by UV-radiation |
16 | 4.5 Release of dangerous substances 4.6 Reaction to fire 4.6.1 General 4.6.2 Mounting and fixing conditions for test samples |
18 | 5 Durability 6 Sampling 7 Assessment and verification of constancy of performance 7.1 General 7.2 Product type determination 7.3 Factory production control 8 Marking and labelling |
19 | Annex A (informative)Example on the frequency of tests for factory production control |
20 | Annex B (normative)Determination of the change of volume of self-levelling cold applied joint sealants B.1 Principle B.2 Apparatus and materials B.3 Preparation of test specimens B.4 Test procedure |
21 | B.5 Calculation and expression of results B.5.1 Change in mass B.5.2 Change in volume |
22 | Annex ZA(informative)Relationship of this European Standard with Regulation (EU) No.305/2011 |