BS EN 13757-3:2018

$215.11

Communication systems for meters – Application protocols

Published By Publication Date Number of Pages
BSI 2018 108
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This draft European Standard specifies application protocols for communication systems for meters and remote reading of meters. This draft European Standard specifies application protocols, especially the M-Bus application protocol. This draft European Standard is intended to be used with the lower layer specifications determined in EN 13757-2, EN 13757-4, EN 13757-5, EN 13757-6 and prEN 13757-7.

PDF Catalog

PDF Pages PDF Title
2 undefined
10 1 95BScope
2 96BNormative references
3 97BTerms and definitions
11 4 98BAbbreviations and symbols
4.1 110BAbbreviations
12 4.2 111BSymbols
5 99BSelection of an application protocol
6 100BM-Bus protocol
6.1 112BGeneral
13 6.2 113BM-Bus data record
6.3 114BData Information Block (DIB)
6.3.1 126BGeneral
6.3.2 127BData Information Field (DIF)
6.3.3 128BData field
15 6.3.4 129BFunction field
6.3.5 130BStorage number
16 6.3.6 131BExtension bit (E)
6.3.7 132BData Information Field Extension (DIFE)
6.3.8 133BTariff information
17 6.3.9 134BSubunit information
6.4 115BValue Information Block (VIB)
6.4.1 135BGeneral
18 6.4.2 136BPrimary VIFs (main table)
19 6.4.3 137BVIF-codes for special purposes
20 6.4.4 138BVIFE-code extension tables
6.4.4.1 145BMain VIFE-code extension table (following VIF = FDh for primary VIF)
23 6.4.4.2 146B2nd level VIFE-code extension table (following VIF = FDh and VIFE = FDh)
6.4.5 139BAlternate VIFE-code extension table (following VIF = FBh for primary VIF)
25 6.4.6 140BCombinable (orthogonal) VIFE-Code extension table
28 6.4.7 141BGeneralized object layer
6.4.8 142BRecord errors
29 6.5 116BManufacturer specific unstructured data block
30 7 101BApplication reset and application select
7.1 117BApplication reset
7.2 118BApplication select with subcode
32 7.3 119BOverview about CI-Fields for Application reset and Application select
33 7.4 120BRules for application selection
7.4.1 143BReset of current slave response
34 7.4.2 144BErroneous application select
7.5 121BRules for block selection
7.6 122BSelected application block in M-Bus Application protocol
8 102BClock synchronization
35 9 103BReport of alarm status (slave to master)
10 104BReport of application error
10.1 123BGeneral
10.2 124BStatus field
10.3 125BGeneral application layer errors
36 11 105BSwitching baud rate for M-Bus link layer according to EN 137572
37 12 106BSynchronize action
13 107BManufacturer specific protocols
14 108BOther application protocols
15 109BImage transfer
38 Annex A 86B(normative)Coding of data records
46 Annex B 87B(normative)Interpretation of hex-codes Ah–Fh in BCD-data fields
B.1 0BGeneral description standard reference
B.1.1 23BGeneral
B.1.2 24BPurpose
B.2 1BDefinition
B.2.1 25BHex code meanings
B.2.2 26BLCD-decoding table
47 Annex C 88B(normative)VIF coding for special units
C.1 2BNon-metric units
C.2 3BPlain text units
48 C.3 4BRemote enablement/disablement of valve/breaker
49 Annex D 89B(informative)Alarm protocol
D.1 5BM-Bus according EN 137572
D.2 6BWireless M-Bus according to EN 137574
50 Annex E 90B(informative)Special sequences for M-Bus devices
E.1 7BVIF/VIFE/VIFE = FDh 97h 1Dh (error flag)
52 E.2 8BVIF/VIFE/VIFE = FDh 9Fh 1Dh for passing remote control on a node
53 E.3 9BClock synchronization
55 Annex F 91B(normative)Transmission of profiles
F.1 10BThe standard load profile
F.2 11BThe M-Bus compact profile
F.2.1 27BGeneral
56 F.2.2 28BThe base value and base parameter
F.2.3 29BThe base time
F.2.4 30BStructure of the compact profile
58 F.2.5 31BTypes of compact profile
F.2.6 32BCompact profile with register numbers (orthogonal VIFE = 1Eh)
59 F.2.7 33BCompact profile (orthogonal VIFE = 1Fh)
F.2.8 34BInverse compact profile (orthogonal VIFE = 13h)
61 Annex G 92B(normative)Compact M-Bus frame
G.1 12BGeneral
G.2 13BCI-fields of the Full and the Compact M-Bus frame
G.2.1 35BGeneral
62 G.2.2 36BFull M-Bus frame
G.2.3 37BM-Bus- Compact frame
63 G.2.4 38BM-Bus-Format frame
G.3 14BCalculation of the Full-Frame-CRC
G.4 15BCalculation of the Format Signature
G.5 16BFrame examples
G.5.1 39BGeneral
64 G.5.2 40BExample without data header
G.5.3 41BExample with short data header, no encryption
G.5.4 42BExample with short data header, encryption mode 5
66 Annex H 93B(normative)Translating M-Bus type record descriptors to OBIS-type record descriptors
H.1 17BGeneral
H.2 18BTranslation of predefined data record types
84 H.3 19BOnline addition of an entry for the M-Bus to OBIS conversion table
85 Annex I 94B(normative)Image Transfer
I.1 20BImage Transfer Phases
I.1.1 43BGeneral
I.1.2 44BTransfer Preparation
86 I.1.3 45BTransfer Synchronization
I.1.4 46BImage Transfer
87 I.1.5 47BImage Validation
I.1.6 48BImage Activation
I.2 21BCommands for Image Transfer
I.2.1 49BGeneral
I.2.2 50BCommand and response structure
88 I.2.3 51BFunction Field
89 I.2.4 52BPrepare command
I.2.4.1 69BGeneral
90 I.2.4.2 70BImage Identifier field
I.2.4.3 71BDate and Time field
91 I.2.4.4 72BPace
I.2.4.5 73BSize Information field
I.2.4.6 74BMAC field
93 I.2.4.7 75BAdditional Information
I.2.5 53BPrepare response
94 I.2.6 54BSynchronize Command
I.2.6.1 76BGeneral
95 I.2.6.2 77BCount Down field
I.2.7 55BTransfer command
I.2.7.1 78BGeneral
I.2.7.2 79BBlock number
96 I.2.7.3 80BRemaining field
I.2.7.4 81BAdditional Information
I.2.7.5 82BImage block
I.2.8 56BTransfer Response
I.2.9 57BCompletion command
97 I.2.10 58BCompletion response
I.2.10.1 83BGeneral
I.2.10.2 84BTotal Number of Lost Blocks
98 I.2.10.3 85BLost Blocks Field
I.2.11 59BState command
I.2.12 60BState Response
99 I.2.13 61BValidate command
100 I.2.14 62BValidate Response
I.2.15 63BActivate command
101 I.2.16 64BActivate Response
102 I.2.17 65BTerminate Command
I.2.18 66BTerminate Response
103 I.2.19 67BActive Images Command
I.2.20 68BActive Images Response
I.3 22BOverview Image Transfer
BS EN 13757-3:2018