Scope
1.1 This specification covers the classification, composition, dimension, and physical properties of mineral fiber (rock, slag, or glass) semi-rigid and rigid board insulation for the use on 0Ā°F (-18Ā°C) cooled surfaces and on heated surfaces up to 1800Ā°F (982Ā°C). Specific applications outside the maximum and minimum temperature limits shall be agreed upon between the supplier and the purchaser.
1.2 For satisfactory performance, properly installed protective vapor retarder or barriers shall be used on below ambient temperature applications to reduce movement of moisture through or around the insulation to the colder surface. Failure to use a vapor barrier can lead to insulation and system damage. Refer to Practice C 921 to aid material selection. Although vapor retarder properties are not part of this specification, properties required in Specification C 1136 are pertinent to applications or performance.
1.3 The orientation of the fibers within the boards is primarily parallel to the principal surface (face). This specification does not cover fabricated pipe and tank wrap insulation where the insulation has been cut and fabricated to provide a fiber orientation that is perpendicular to the principal large surface (face).
1.4 This standard does not purport to provide the performance requirements of hourly-rated fire systems. Consult the manufacturer for the appropriate system.
1.5 The values stated in inch-pound units shall be regarded as the standard. The SI equivalents of inch-pound units are given in parentheses for information only and are approximate.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
block; board; high temperature; mineral fiber insulation; rock fiber; shot; shot content; slag fiber; Block and board thermal insulation
ICS Code
ICS Number Code 91.100.60 (Thermal and sound insulating materials)
DOI: 10.1520/C0612-04E01
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Terminology Classification Ordering Information TABLE 1 |
3 | Materials and Manufacture Physical Properties Qualification Requirements Dimensions, Mass, and Permissible Variations Workmanship, Finish and Appearance Sampling TABLE 2 |
4 | Test Methods TABLE 3 |
5 | Inspection Rejection Certification Packaging and Package Marking Keywords |