{"id":262645,"date":"2024-10-19T17:26:12","date_gmt":"2024-10-19T17:26:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-6400-22018\/"},"modified":"2024-10-25T13:16:59","modified_gmt":"2024-10-25T13:16:59","slug":"bs-6400-22018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-6400-22018\/","title":{"rendered":"BS 6400-2:2018"},"content":{"rendered":"
This British Standard specifies requirements for the installation, exchange, relocation, maintenance and removal of credit or prepayment or smart meters of the following types: diaphragm, ultrasonic and thermal mass gas meters with a maximum capacity not exceeding 6 m3<\/sup>\/h.<\/p>\n NOTE 1 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognized that each of these tasks can be performed by the same person.<\/p>\n<\/blockquote>\n NOTE 2 For smart meters this standard only covers the associated gas work.<\/p>\n<\/blockquote>\n This part of BS 6400 is applicable to primary meter installations:<\/p>\n supplied with 2nd family gases from medium pressure gas distribution systems with a maximum operating pressure exceeding 75 mbar but not exceeding 2 bar and with a design maximum incidental pressure of 2.7 bar;<\/p>\n NOTE 3 Some legacy MP networks can operate at a design minimum pressure (DMP) of 35 mbar, 65 mbar, 105 mbar, 180 mbar and 270 mbar.<\/p>\n<\/blockquote>\n<\/li>\n only fitted downstream of the emergency control valve;<\/p>\n<\/li>\n that utilize a pressure control and protection system contained within a regulator assembly that is downstream of the emergency control valve;<\/p>\n<\/li>\n where all gas fittings subjected to medium pressure have been pre-assembled and where strength and gas tightness testing has been undertaken on the regulator assembly at the factory;<\/p>\n NOTE 4 It is recognized that the final connection(s) to the gas service would not be subject to a strength test.<\/p>\n<\/blockquote>\n<\/li>\n where the operating pressure at the outlet of the meter is nominally 21 mbar; and<\/p>\n<\/li>\n installed external to the building.<\/p>\n<\/li>\n<\/ol>\n NOTE 5 Installation, exchange, relocation, maintenance and removal of a secondary meter with a maximum capacity of 6 m3<\/sup>\/h is specified in BS 6400\u20111.<\/p>\n<\/blockquote>\n NOTE 6 Installation pipework is specified in BS 6891.<\/p>\n<\/blockquote>\n NOTE 7 Service pipes (including the emergency control valve) are specified in the Institution of Gas Engineers and Managers\u2019 publication on gas services, IGE\/TD\/4 [18].<\/p>\n<\/blockquote>\n NOTE 8 All pressures quoted in this standard are gauge pressures and all pressure absorption values are for natural gas unless otherwise specified.<\/p>\n<\/blockquote>\n NOTE 9 Additional guidance on domestic gas systems can be found in the European functional standards BS EN 1775 and BS EN 12279.<\/p>\n<\/blockquote>\n NOTE 10 Additional guidance on measuring systems can be found in the European functional standard BS EN 1776.<\/p>\n<\/blockquote>\n Specification for installation, exchange, relocation, maintenance and removal of gas meters with a maximum capacity not exceeding 6 m3<\/sup>\/h – Medium pressure (2nd family gases)<\/b><\/p>\n\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 6<\/td>\n Foreword <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 11<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 15<\/td>\n 4 Planning and exchange of information
4.1 Consultation <\/td>\n<\/tr>\n\n 16<\/td>\n 4.2 Coordination of work
4.3 Non-return valve
4.4 Multiple domestic meter installations
5 Competency <\/td>\n<\/tr>\n\n 17<\/td>\n Table 1 \u2014 Approval bodies and statutory regulations by country\/territory
Table 2 \u2014 Competence requirements by country\/territory <\/td>\n<\/tr>\n\n 18<\/td>\n 6 Design
6.1 General <\/td>\n<\/tr>\n\n 19<\/td>\n Figure 1 \u2014 Arrangement of a MP meter installation and options for the arrangement of the pressure control and protection system <\/td>\n<\/tr>\n \n 20<\/td>\n Figure 1 \u2014 Arrangement of a MP meter installation and options for the arrangement of the pressure control and protection system <\/td>\n<\/tr>\n \n 21<\/td>\n Figure 1 \u2014 Arrangement of a MP meter installation and options for the arrangement of the pressure control and protection system <\/td>\n<\/tr>\n \n 22<\/td>\n Figure 1 \u2014 Arrangement of a MP meter installation and options for the arrangement of the pressure control and protection system <\/td>\n<\/tr>\n \n 23<\/td>\n Figure 1 \u2014 Arrangement of a MP meter installation and options for the arrangement of the pressure control and protection system
6.2 Pressure control <\/td>\n<\/tr>\n\n 24<\/td>\n 6.3 Regulator assembly
6.4 Pressure control and protection system <\/td>\n<\/tr>\n\n 25<\/td>\n 6.5 Low pressure regulator
Figure 2a \u2014 Typical IGEM\/GM\/PRS\/28 [N5] meter regulator <\/td>\n<\/tr>\n\n 26<\/td>\n Figure 2b \u2014 Typical IGEM\/GM\/PRS\/29 [N6] meter regulators
6.6 Vent pipe <\/td>\n<\/tr>\n\n 27<\/td>\n 6.7 Meter <\/td>\n<\/tr>\n \n 29<\/td>\n Figure 3 \u2014 Connections on 6 m3\/h metal case meter <\/td>\n<\/tr>\n \n 30<\/td>\n Figure 4 \u2014 Connections on 6 m3\/h plastic case meters intended for semi-concealed installation
6.8 Emergency control valve
6.9 Meter inlet valve <\/td>\n<\/tr>\n\n 31<\/td>\n 6.10 Pliable connector
6.11 Pressure test point
6.12 Interconnecting pipework
6.13 Location of meter installation <\/td>\n<\/tr>\n\n 32<\/td>\n 6.14 Meter housing <\/td>\n<\/tr>\n \n 33<\/td>\n 6.15 Proximity distances for meter boxes and vent pipe tips <\/td>\n<\/tr>\n \n 34<\/td>\n Figure 5 \u2014 Typical meter boxes <\/td>\n<\/tr>\n \n 35<\/td>\n Figure 6a) \u2014 Minimum proximity distances from a meter housing (Mh) to openings into a property or to adjacent electrical equipment <\/td>\n<\/tr>\n \n 36<\/td>\n Figure 6b) \u2014 Minimum proximity distances from a vent pipe tip (Vpt) to openings into a property or to adjacent electrical equipment <\/td>\n<\/tr>\n \n 37<\/td>\n Table 3 \u2014 Minimum proximity distances for meter boxes and relief valve vent pipe tips
7 Gas transporter appraisal of primary meter installation
8 Meter work
8.1 Risk assessment <\/td>\n<\/tr>\n\n 38<\/td>\n Figure 7 \u2014 Non-contact voltage detector (single pole): Example
8.2 Fitting a meter installation <\/td>\n<\/tr>\n\n 39<\/td>\n 8.3 Handling and care <\/td>\n<\/tr>\n \n 40<\/td>\n Figure 8 \u2014 Typical MP meter installations <\/td>\n<\/tr>\n \n 42<\/td>\n 8.4 Pre-installation checks and safety precautions <\/td>\n<\/tr>\n \n 44<\/td>\n 8.5 Emergency control valve
8.6 Protective bonding conductor
8.7 Temporary continuity bond <\/td>\n<\/tr>\n\n 45<\/td>\n 8.8 Securing the meter installation
8.9 Regulator assembly <\/td>\n<\/tr>\n\n 46<\/td>\n 8.10 Pliable connector
9 Testing, purging and commissioning of the regulator assembly
10 Fitting, testing and purging the meter
10.1 General
10.2 Installations conforming to Figure 1a) and Figure 1b) <\/td>\n<\/tr>\n\n 47<\/td>\n 10.3 Installations conforming to Figure 1c) and Figure 1d)
11 Commissioning of the meter installation
11.1 Regulator <\/td>\n<\/tr>\n\n 48<\/td>\n Table 4 \u2014 Appliance gas flow rates for checking meter regulator performance
11.2 Meter
12 Notices
12.1 General <\/td>\n<\/tr>\n\n 49<\/td>\n 12.2 Emergency notices <\/td>\n<\/tr>\n \n 50<\/td>\n 12.3 Meter installation <\/td>\n<\/tr>\n \n 51<\/td>\n Figure 9 \u2014 Typical meter installation notices
12.4 Installations incorporating a secondary meter <\/td>\n<\/tr>\n\n 52<\/td>\n 12.5 Meter housing notice
12.6 Emergency control valve
13 Meter exchange and\/or replacement of other gas fittings
13.1 General
13.2 Temporary continuity bond <\/td>\n<\/tr>\n\n 53<\/td>\n 13.3 Carrying out the work
14 Meter relocation
14.1 General
14.2 Inspection of existing installation
14.3 Design <\/td>\n<\/tr>\n\n 54<\/td>\n 14.4 Carrying out the work
14.5 Gas tightness testing and purging
14.6 Commissioning, notices and records
15 Meter installation removal <\/td>\n<\/tr>\n\n 55<\/td>\n 16 Records <\/td>\n<\/tr>\n \n 56<\/td>\n 17 Post installation checks
18 Inspection and maintenance
18.1 General
18.2 Five year inspection and maintenance of meter housing and meter installation <\/td>\n<\/tr>\n\n 57<\/td>\n 18.3 Ten year inspection and maintenance of meter housing and meter installation <\/td>\n<\/tr>\n \n 58<\/td>\n Annex A (normative)\u2002 Sizing of meters
Table A.1 \u2014 Diversity factors of appliances for meter sizing <\/td>\n<\/tr>\n\n 59<\/td>\n Annex B (normative)\u2002 Operating pressure limits
Table B.1 \u2014 Operating pressure limits for meter installation pressure control and protection systems <\/td>\n<\/tr>\n\n 61<\/td>\n Annex C (normative)\u2002 Testing, purging and commissioning of the regulator assembly <\/td>\n<\/tr>\n \n 69<\/td>\n Figure C.1 \u2014 Typical arrangement of test and purge apparatus <\/td>\n<\/tr>\n \n 70<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2018<\/td>\n 74<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":262647,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1275,2641],"product_tag":[],"class_list":{"0":"post-262645","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-140-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/262645","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/262647"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=262645"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=262645"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=262645"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}