Shopping Cart

No products in the cart.

BS IEC 61988-2-6:2015

$142.49

Plasma display panels – Measuring methods. APL dependent gamma and colour characteristics

Published By Publication Date Number of Pages
BSI 2015 30
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61988-2-6:2015(E) defines the measuring methods for gamma and colour gamut characteristics as a function of the APL for a PDP module (plasma display module). Generally, the luminance level of a PDP module is dependent on the APL (average picture level) of input images. Varying the input levels causes a change of the chromaticity of RGB primary colours. This standard also defines the measuring methods of tone characteristics and chromaticity characteristics with varying APLs. This standard is based on the assumption that the inverse-gamma circuit is inside the module.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
6 FOREWORD
8 1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
9 3.2 Abbreviations
4 Measurement equipment
4.1 Video signal generator
4.2 Non-contact LMD (light measurement device)
4.3 Contact LMD
5 Measurement conditions
5.1 General
5.2 Setup conditions
10 5.3 Measuring layout
Figures
Figure 1 – Measuring layout for non-contact measurement
11 5.4 Input signal level and picture level
Figure 2 – Measuring layout for contact measurement
12 6 Measuring methods of tone characteristics
6.1 Purpose
Figure 3 – Input signals and signal processing in a PDP module
13 6.2 Input signals
6.2.1 General
6.2.2 11-step grey bar with fixed APL
14 6.2.3 Single grey window with fixed APL
Figure 4 – An example of an 11-step grey-bar pattern
Figure 5 – Example of 4 % window pattern for measuring the tone characteristics
15 6.2.4 11-step RGB bar and single colour window with fixed APL
Figure 6 – RGB bar and single window pattern
16 6.3 Measuring procedure
17 6.4 Expression of results
6.4.1 Measurement report
Figure 7 – An example of results of gamma characteristics for each APL
Tables
Table 1 – An example of a tone measurement report
18 6.4.2 Gamma calculation
19 Figure 8 – Example plots for calculated gamma values by APL
Table 2 – Example of gamma reporting form (for each APL )
20 Figure 9 – Example plots for CCT characteristics by APL
Figure 10 – Example plots for ∆u’v’ characteristics by APL
21 7 Measuring methods of colour gamut by APL
7.1 Purpose
7.2 Primary and secondary colour patterns by APL
7.3 Measuring procedure
Figure 11 – 4 % C, M, and Y single window pattern
22 7.4 Evaluation of colour accuracy
7.5 Evaluation of colour gamut
Figure 12 – ITU-R Rec. BT.709-5 standard coordinates of primary and secondary colours
23 7.6 Expression of results
Figure 13 – Example showing a measured primary, a reference, and an overlapped gamut area
Table 3 – An example of gamut areas for evaluation of colour gamut
24 Table 4 – An example of primary and secondary colour measurement report
26 Figure 14 – The measured colour gamut plots by APL
27 Annex A (informative) Use of ITU-R Rec. BT.709-5 signal
Table A.1 – Digital data and signal level in ITU-R Rec. BT.709-5
28 Bibliography
BS IEC 61988-2-6:2015